Basic Info.
Model NO.
Amazing RTO
Type
Incinerator
High Efficiency
100
Energy Saving
100
Low Maintenance
100
Easy Operation
100
Trademark
Bjamazing
Transport Package
Overseas
Specification
111
Origin
China
HS Code
2221111
Product Description
RTO
Regenerative Thermal Oxidizer
Compared with traditional catalytic combustion,; direct thermal oxidizer,; RTO has the merits of high heating efficiency,; low operation cost,; and the ability to treat large flux low concentration waste gas.; When VOCs concentration is high,; secondary heat recycle can be realized,; which will greatly reduce the operation cost.; Because RTO can preheat the waste gas by levels through ceramic heat accumulator,; which could make the waste gas to be completely heated and cracked with no dead corner(treatment efficiency>99%);,;which reduce the NOX in the Exhausting gas,; if the VOC density >1500mg/Nm3,; when the waste gas reach cracking area,; it has been heated up to cracking temperature by heat accumulator,; the burner will be closed under this condition.;
RTO can be devided into chamber type and rotary type according to difference operation mode.; Rotary type RTO has advantages in system pressure,; temperature stability,; investment amount,; etc
RTO types | Efficiency | Pressure change (mmAq); | Size | (max);Treatment volume | |
Treatment efficiency | Heat recycle efficiency | ||||
Rotary type RTO | 99 % | 97 % | 0-4 | small (1 time); | 50000Nm3/h |
Three chamber type RTO | 99 % | 97 % | 0-10 | Large (1.;5times); | 100000Nm3/h |
Two chamber type RTO | 95 % | 95 % | 0-20 | middle (1.;2times); | 100000Nm3/h |
Regenerative Thermal Oxidizer,; Regenerative Thermal Oxidizer,; Regenerative Thermal Oxidizer,; Thermal Oxidizer,; Thermal Oxidizer,; Thermal Oxidizer,; oxidizer,; oxidizer,; oxidizer,; incinerator,; incinerator,; incinerator,; waste gas treatment,; waste gas treatment,; waste gas treatment,; VOC treatment,; VOC treatment,; VOC treatment,; RTO,; RTO,; RTO,; Rotary RTO,; Rotary RTO,; Rotary RTO,; Chamber RTO,; Chamber RTO,; Chamber RTO
Address: 8 floor, E1, Pinwei building, Dishengxi road, Yizhuang, ZheJiang , China
Business Type: Manufacturer/Factory, Trading Company
Business Range: Electrical & Electronics, Industrial Equipment & Components, Manufacturing & Processing Machinery, Metallurgy, Mineral & Energy
Management System Certification: ISO 9001, ISO 14001
Main Products: Rto, Color Coating Line, Galvanizing Line, Air Knife, Spares for Processing Line, Coater, Independent Equipments, Sink Roll, Revamping Project, Blower
Company Introduction: ZheJiang Amazing Science & Technology Co., Ltd is a thriving Hi-tech company, located in ZheJiang Economic and Technological Development Area(BDA). Adhering to the concept of Realistic, Innovative, Focused and Efficient, our company mainly serve the waste gas treatment (VOCs) Industry and metallurgical equipment of China and even whole world. We have advanced technology and rich experience in VOCs waste gas treatment project, the reference of which has been successfully applied to the industry of coating, rubber, electronic, printing, etc. We also have years of technology accumulation in the research and manufacturing of flat steel processing line, and possess nearly 100 of application example.
Our company focus on the research, design, manufacturing, installation and commissioning of VOCs organic waste gas treatment system and the revamping and updating project for energy saving and environmental protection of flat steel processing line. We can provide customers the complete solutions for environmental protection, energy saving, product quality improvement and other aspects.
We are also engaged in various spares and independent equipment for color coating line, galvanizing line, pickling line, like roller, coupler, heat exchanger, recuperator, air knife, blower, welder, tension leveler, skin pass, expansion joint, shear, jointer, stitcher, burner, radiant tube, gear motor, reducer, etc.
What is the difference between a regenerative thermal oxidizer and a thermal oxidizer?
A regenerative thermal oxidizer (RTO) and a thermal oxidizer are both types of air pollution control devices used for the treatment of volatile organic compounds (VOCs) and other air pollutants. While they share the same purpose, there are distinct differences between the two technologies.
Here are the key differences between a regenerative thermal oxidizer and a thermal oxidizer:
- Operating Principle: The fundamental difference lies in the operating principle. A thermal oxidizer operates by using high temperature alone to oxidize and destroy pollutants. It typically relies on a burner or other heat sources to raise the temperature of the exhaust gases to the required level for combustion. In contrast, an RTO utilizes a regenerative heat exchanger system to preheat the incoming exhaust gases by capturing and transferring heat from the outgoing gases. This heat exchange mechanism significantly improves the overall energy efficiency of the system.
- Heat Recovery: Heat recovery is a distinctive feature of an RTO. The regenerative heat exchanger in an RTO allows for the recovery of a significant amount of heat from the outgoing gases. This recovered heat is then used to preheat the incoming gases, reducing the energy consumption of the system. In a typical thermal oxidizer, heat recovery is limited or absent, resulting in higher energy requirements.
- Energy Efficiency: Due to the heat recovery mechanism, RTOs are generally more energy-efficient compared to traditional thermal oxidizers. The regenerative heat exchanger in an RTO allows for thermal efficiencies of 95% or higher, meaning that a significant portion of the energy input is recovered and utilized within the system. Thermal oxidizers, on the other hand, typically have lower thermal efficiencies.
- Operating Costs: The higher energy efficiency of RTOs translates into lower operating costs over the long term. The reduced energy consumption can result in significant savings in fuel or electricity expenses compared to thermal oxidizers. However, the initial capital investment for an RTO is generally higher than that of a thermal oxidizer due to the complexity of the regenerative heat exchanger system.
- Control of Pollutant Concentrations: RTOs are better suited for handling variable pollutant concentrations compared to thermal oxidizers. The regenerative heat exchanger system in an RTO allows for better control and adjustment of operating parameters to accommodate fluctuations in pollutant concentrations. Thermal oxidizers are typically less adaptable to varying pollutant loads.
In summary, the main differences between a regenerative thermal oxidizer and a thermal oxidizer lie in the operating principle, heat recovery capabilities, energy efficiency, operating costs, and control of pollutant concentrations. RTOs offer higher energy efficiency, better control of pollutant concentrations, and lower operating costs, but they require a higher initial investment compared to traditional thermal oxidizers.
How do regenerative thermal oxidizers handle variations in pollutant composition?
Regenerative thermal oxidizers (RTOs) are designed to handle variations in pollutant composition effectively. RTOs are commonly used for treating volatile organic compounds (VOCs) and hazardous air pollutants (HAPs) emitted from various industrial processes. Here are some key points regarding how RTOs handle variations in pollutant composition:
- Thermal Oxidation Process: RTOs utilize a thermal oxidation process to eliminate pollutants. The process involves raising the temperature of the exhaust gas to a level where the pollutants react with oxygen and are oxidized to carbon dioxide (CO2) and water vapor. This high-temperature oxidation process is effective in treating a wide range of pollutants, regardless of their specific composition.
- Wide Range of Pollutant Compatibility: RTOs are designed to handle a broad spectrum of pollutants, including VOCs and HAPs with varying chemical compositions. The high operating temperatures in the RTO, typically between 1400°F to 1600°F (760°C to 870°C), ensure that a wide range of organic compounds can be effectively oxidized, regardless of their molecular structure or chemical makeup.
- Residence Time and Dwell Time: RTOs provide sufficient residence time and dwell time for the exhaust gas within the oxidizer. The exhaust gas is directed through a heat exchange system, where it passes through ceramic media beds or heat exchange media. These media beds absorb the heat from the high-temperature combustion chamber and transfer it to the incoming exhaust gas. The extended residence time and dwell time ensure that even complex or less reactive pollutants have enough contact time with the elevated temperature to be effectively oxidized.
- Heat Recovery: RTOs incorporate heat recovery systems that maximize thermal efficiency. The heat exchangers within the RTO capture and transfer heat from the outgoing exhaust gas to the incoming process stream. This heat exchange process helps maintain the high operating temperatures required for effective pollutant destruction while minimizing the energy consumption of the system. The ability to recover and reuse heat also contributes to the RTO’s ability to handle variations in pollutant composition.
- Advanced Control Systems: RTOs employ advanced control systems to monitor and optimize the oxidation process. These control systems continuously monitor parameters such as temperature, flow rates, and pollutant concentrations. By adjusting the operating conditions in response to variations in pollutant composition, the control systems ensure optimal performance and maintain high destruction efficiencies.
In summary, RTOs handle variations in pollutant composition by utilizing a thermal oxidation process, accommodating a wide range of pollutants, providing sufficient residence time and dwell time, incorporating heat recovery systems, and employing advanced control systems. These features allow RTOs to effectively treat emissions with different pollutant compositions, ensuring high destruction efficiencies and compliance with environmental regulations.
What are the maintenance requirements for a regenerative thermal oxidizer?
Maintaining a regenerative thermal oxidizer (RTO) is essential to ensure its optimal performance, longevity, and compliance with environmental regulations. Here are some key maintenance requirements for an RTO:
- Regular Inspections: Conduct routine inspections to identify any signs of wear, corrosion, or damage to the RTO components. This includes inspecting valves, dampers, fans, combustion chambers, heat exchangers, and ceramic media beds. Inspections help detect potential issues early and allow for timely repairs or replacements.
- Cleaning and Replacement of Components: Clean or replace components as needed to maintain proper functionality. This may include cleaning clogged or fouled heat exchanger surfaces, replacing damaged or worn-out valves and dampers, and periodically replacing the ceramic media beds if they become degraded or contaminated.
- Monitoring Operating Parameters: Regularly monitor and record operating parameters such as temperature, airflow, pressure differentials, and gas concentrations. Deviations from normal operating ranges can indicate potential problems or inefficiencies that require attention.
- Calibration of Instruments: Calibrate instruments and sensors used for monitoring and control purposes to ensure accurate measurement of parameters such as temperature, pressure, and flow rates. Proper calibration helps maintain reliable and precise operation of the RTO.
- Cleaning of Heat Recovery System: Clean the heat recovery system, including the heat exchanger surfaces, to remove any accumulated particulate matter or fouling. This ensures efficient heat transfer and prevents the buildup of deposits that can reduce the RTO’s performance.
- Compliance with Safety Standards: Adhere to safety standards and guidelines for working with the RTO. This includes proper lockout/tagout procedures during maintenance activities, wearing appropriate personal protective equipment, and following safety protocols to minimize risks to personnel and equipment.
- Documentation and Record-Keeping: Maintain comprehensive records of maintenance activities, inspections, repairs, and any modifications made to the RTO. Documentation helps track the equipment’s history, aids in troubleshooting, and provides a record of compliance with regulatory requirements.
It’s important to note that the specific maintenance requirements may vary depending on the RTO manufacturer’s recommendations, the design of the system, the operating conditions, and applicable regulatory requirements. Following the manufacturer’s guidelines, conducting regular inspections, and implementing a proactive maintenance program tailored to the specific RTO are crucial for ensuring its reliable operation and longevity.
editor by Dream 2024-05-08