Basic Info.
Model NO.
Amazing RTO
Type
Incinerator
Energy Saving
100
Easy for Operation
100
High Efficiency
100
Less Maintenance
100
Trademark
Bjamazing
Transport Package
Overseas Wooden
Specification
180*24
Origin
China
HS Code
8416100000
Product Description
RTO
Regenerative Thermal Oxidizer
Compared with traditional catalytic combustion,; direct thermal oxidizer,; RTO has the merits of high heating efficiency,; low operation cost,; and the ability to treat large flux low concentration waste gas.; When VOCs concentration is high,; secondary heat recycle can be realized,; which will greatly reduce the operation cost.; Because RTO can preheat the waste gas by levels through ceramic heat accumulator,; which could make the waste gas to be completely heated and cracked with no dead corner(treatment efficiency>99%);,;which reduce the NOX in the Exhausting gas,; if the VOC density >1500mg/Nm3,; when the waste gas reach cracking area,; it has been heated up to cracking temperature by heat accumulator,; the burner will be closed under this condition.;
RTO can be devided into chamber type and rotary type according to difference operation mode.; Rotary type RTO has advantages in system pressure,; temperature stability,; investment amount,; etc
RTO types | Efficiency | Pressure change (mmAq); | Size | (max);Treatment volume | |
Treatment efficiency | Heat recycle efficiency | ||||
Rotary type RTO | 99 % | 97 % | 0-4 | small(1 time); | 50000Nm3/h |
Three chamber type RTO | 99 % | 97 % | 0-10 | Large (1.;5times); | 100000Nm3/h |
Two chamber type RTO | 95 % | 95 % | 0-20 | middle(1.;2times); | 100000Nm3/h |
Regenerative Thermal Oxidizer,; Regenerative Thermal Oxidizer,; Regenerative Thermal Oxidizer,; Thermal Oxidizer,; Thermal Oxidizer,; Thermal Oxidizer,; oxidizer,; oxidizer,; oxidizer,; incinerator,; incinerator,; incinerator,; waste gas treatment,; waste gas treatment,; waste gas treatment,; VOC treatment,; VOC treatment,; VOC treatment,; RTO,; RTO,; RTO,; RTO,; RTO,; RTO
Address: 8 floor, E1, Pinwei building, Dishengxi road, Yizhuang, ZheJiang , China
Business Type: Manufacturer/Factory, Trading Company
Business Range: Electrical & Electronics, Industrial Equipment & Components, Manufacturing & Processing Machinery, Metallurgy, Mineral & Energy
Management System Certification: ISO 9001, ISO 14001
Main Products: Rto, Color Coating Line, Galvanizing Line, Air Knife, Spares for Processing Line, Coater, Independent Equipments, Sink Roll, Revamping Project, Blower
Company Introduction: ZheJiang Amazing Science & Technology Co., Ltd is a thriving Hi-tech company, located in ZheJiang Economic and Technological Development Area(BDA). Adhering to the concept of Realistic, Innovative, Focused and Efficient, our company mainly serve the waste gas treatment (VOCs) Industry and metallurgical equipment of China and even whole world. We have advanced technology and rich experience in VOCs waste gas treatment project, the reference of which has been successfully applied to the industry of coating, rubber, electronic, printing, etc. We also have years of technology accumulation in the research and manufacturing of flat steel processing line, and possess nearly 100 of application example.
Our company focus on the research, design, manufacturing, installation and commissioning of VOCs organic waste gas treatment system and the revamping and updating project for energy saving and environmental protection of flat steel processing line. We can provide customers the complete solutions for environmental protection, energy saving, product quality improvement and other aspects.
We are also engaged in various spares and independent equipment for color coating line, galvanizing line, pickling line, like roller, coupler, heat exchanger, recuperator, air knife, blower, welder, tension leveler, skin pass, expansion joint, shear, jointer, stitcher, burner, radiant tube, gear motor, reducer, etc.
Can regenerative thermal oxidizers be used for treating industrial wastewater?
No, regenerative thermal oxidizers (RTOs) are not typically used for treating industrial wastewater. RTOs are specifically designed for air pollution control and the treatment of gaseous pollutants, such as volatile organic compounds (VOCs) and hazardous air pollutants (HAPs).
Here are some key points to consider regarding the use of RTOs for treating industrial wastewater:
- Operating Principle: RTOs rely on the combustion of pollutants in the gas phase. They utilize high temperatures to thermally oxidize gaseous pollutants, converting them into carbon dioxide and water vapor. However, wastewater treatment involves the removal or transformation of contaminants dissolved or suspended in water, which requires different treatment mechanisms.
- Wastewater Treatment Technologies: Wastewater treatment typically involves processes such as physical separation, chemical treatment, biological treatment, and other specialized techniques depending on the nature of the contaminants. Common wastewater treatment technologies include activated sludge systems, sedimentation tanks, chemical precipitation, filtration, and various other methods tailored to specific wastewater characteristics.
- Environmental Regulations: Industrial wastewater treatment is subject to stringent environmental regulations and discharge standards that govern the quality of effluent released into water bodies. Compliance with these regulations requires the implementation of appropriate wastewater treatment technologies specifically designed for the removal or reduction of contaminants in water, rather than air pollution control technologies like RTOs.
- Integration with Wastewater Treatment Systems: While RTOs are not used for wastewater treatment, they may be integrated into overall industrial process systems where wastewater treatment is also required. In such cases, separate wastewater treatment technologies are employed to treat the wastewater, and RTOs are used to address air emissions resulting from the wastewater treatment process or other industrial operations.
In summary, regenerative thermal oxidizers are not suitable for treating industrial wastewater. They are designed for air pollution control and the destruction of gaseous pollutants. For effective wastewater treatment, industries should employ appropriate wastewater treatment technologies specifically designed for the removal or transformation of contaminants in water.
How do regenerative thermal oxidizers handle particulate matter buildup in the system?
Regenerative thermal oxidizers (RTOs) employ various mechanisms to handle particulate matter buildup in the system. Particulate matter, such as dust, soot, or other solid particles, can accumulate over time and potentially affect the performance and efficiency of the RTO. Here are some ways RTOs handle particulate matter buildup:
- Pre-filtration: RTOs can incorporate pre-filtration systems, such as cyclones or bag filters, to remove larger particulate matter before it enters the oxidizer. These pre-filters capture and collect the particles, preventing them from entering the RTO and reducing the potential for buildup.
- Self-Cleaning Effect: RTOs are designed to have a self-cleaning effect on the heat exchange media. During the operation of the RTO, the flow of hot exhaust gases through the media can cause the particles to burn or disintegrate, minimizing their accumulation. The high temperatures and turbulent flow help maintain clean surfaces on the media, reducing the risk of significant particulate buildup.
- Purge Cycle: RTOs typically incorporate purge cycles as part of their operation. These cycles involve introducing a small flow of clean air or gas into the system to purge any residual particulate matter. The purge air helps dislodge or burn off any particles adhering to the media, ensuring their continuous cleaning.
- Periodic Maintenance: Regular maintenance is essential to prevent excessive particulate matter buildup in the RTO. Maintenance activities may include inspecting and cleaning the heat exchange media, checking and replacing any worn-out gaskets or seals, and monitoring the system for any signs of particulate accumulation. Regular maintenance helps ensure optimal performance and minimizes the risk of operational issues associated with particulate matter buildup.
- Monitoring and Alarms: RTOs are equipped with monitoring systems that track various parameters such as pressure differentials, temperatures, and flow rates. These systems can detect any abnormal conditions or excessive pressure drops that may indicate particulate matter buildup. Alarms and alerts can be triggered to notify operators, prompting them to take appropriate action, such as initiating maintenance or cleaning procedures.
It is important to note that the specific strategies employed to handle particulate matter buildup may vary depending on the design and configuration of the RTO, as well as the characteristics of the particulate matter being treated. RTO manufacturers and operators should consider these factors and implement appropriate measures to ensure the effective management of particulate matter in the system.
By incorporating pre-filtration, utilizing the self-cleaning effect, implementing purge cycles, conducting regular maintenance, and employing monitoring systems, RTOs can effectively handle and mitigate particulate matter buildup, maintaining their performance and efficiency over time.
How do regenerative thermal oxidizers handle start-up and shutdown procedures?
Regenerative thermal oxidizers (RTOs) have specific procedures for start-up and shutdown to ensure safe and efficient operation. These procedures are designed to optimize the performance of the RTO and minimize any potential risks. Here is an overview of how RTOs handle start-up and shutdown:
- Start-up Procedure: During start-up, the RTO goes through a series of steps to reach its operating temperature. The start-up procedure typically involves the following stages:
- Purge Stage: The RTO is purged with clean air or an inert gas to remove any potential flammable or explosive gases that may have accumulated during the shutdown period.
- Preheat Stage: The RTO’s heat exchangers are preheated using a burner or an auxiliary heat source. This gradually increases the temperature of the heat exchange media (typically ceramic or metallic beds) and the combustion chamber.
- Heat Soak Stage: Once the heat exchangers reach a certain temperature, the RTO enters the heat soak stage. In this stage, the heat exchangers are fully heated, and the RTO operates in a self-sustaining mode, with the combustion chamber temperature being maintained primarily by the heat released from the oxidation of pollutants in the exhaust gas.
- Normal Operation: After the heat soak stage, the RTO is considered to be in normal operation mode, where it maintains the desired operating temperature and treats the exhaust gas containing pollutants.
- Shutdown Procedure: The shutdown procedure of an RTO is aimed at safely and efficiently stopping the operation of the system. The procedure typically involves the following steps:
- Cool Down: The RTO is gradually cooled down by reducing the flow of the exhaust gas and the supply of combustion air. This helps to prevent thermal stress on the equipment and minimize the risk of fires or other safety hazards.
- Heat Recovery: During the cool-down phase, the RTO may employ heat recovery techniques to capture and utilize the residual heat for other purposes, such as preheating incoming process air or water.
- Purge: Once the RTO has cooled down sufficiently, a purge cycle is initiated to remove any residual gases or contaminants from the system. This helps to ensure a clean and safe environment for maintenance activities or subsequent start-ups.
- Complete Shutdown: After the purge cycle, the RTO is considered to be in a fully shut-down state, and it can remain in this state until the next start-up is initiated.
It is important to note that the specific start-up and shutdown procedures for an RTO may vary depending on the design and manufacturer. Manufacturers typically provide detailed guidelines and instructions for operating their specific RTO models, and it is crucial to follow these guidelines to ensure safe and efficient operation.
editor by Dream 2024-05-06