基本訊息

型號

Amazing RTO

類型

Incinerator

Energy Saving

100

Easy for Operation

100

High Efficiency

100

Less Maintenance

100

商標

Bjamazing

運輸套餐

Overseas Wooden

Specification

180*24

起源

China

HS Code

8416100000

產品描述

RTO

 

蓄熱式熱氧化器

Compared with traditional catalytic combustion,; direct thermal oxidizer,; RTO has the merits of high heating efficiency,; low operation cost,; and the ability to treat large flux low concentration waste gas.; When VOCs concentration is high,; secondary heat recycle can be realized,; which will greatly reduce the operation cost.; Because RTO can preheat the waste gas by levels through ceramic heat accumulator,; which could make the waste gas to be completely heated and cracked with no dead corner(treatment efficiency>99%);,;which reduce the NOX in the Exhausting gas,; if the VOC density >1500mg/Nm3,; when the waste gas reach cracking area,; it has been heated up to cracking temperature by heat accumulator,; the burner will be closed under this condition.;

RTO can be devided into chamber type and rotary type according to difference operation mode.; Rotary type RTO has advantages in system pressure,; temperature stability,; investment amount,; etc
 

RTO types   Efficiency Pressure change
(mmAq);
尺寸 (max);Treatment volume  
 
Treatment efficiency  Heat recycle efficiency  
Rotary type RTO 99 % 97 % 0-4 small(1 time); 50000Nm3/h  
Three chamber type RTO 99 %    97 %   0-10 Large
(1.;5times);
100000Nm3/h
Two chamber type RTO 95 % 95 % 0-20 middle(1.;2times); 100000Nm3/h  

Regenerative Thermal Oxidizer,; Regenerative Thermal Oxidizer,; Regenerative Thermal Oxidizer,;  Thermal Oxidizer,; Thermal Oxidizer,; Thermal Oxidizer,; oxidizer,; oxidizer,; oxidizer,; incinerator,; incinerator,; incinerator,; waste gas treatment,; waste gas treatment,; waste gas treatment,; VOC treatment,; VOC treatment,; VOC treatment,; RTO,; RTO,; RTO,; RTO,; RTO,; RTO

Address: 8 floor, E1, Pinwei building, Dishengxi road, Yizhuang, ZheJiang , China

業務類型: 製造商/工廠, 貿易公司

Business Range: Electrical & Electronics, Industrial Equipment & Components, Manufacturing & Processing Machinery, Metallurgy, Mineral & Energy

Management System Certification: ISO 9001, ISO 14001

Main Products: Rto, Color Coating Line, Galvanizing Line, Air Knife, Spares for Processing Line, Coater, Independent Equipments, Sink Roll, Revamping Project, Blower

Company Introduction: ZheJiang Amazing Science & Technology Co., Ltd is a thriving Hi-tech company, located in ZheJiang Economic and Technological Development Area(BDA). Adhering to the concept of Realistic, Innovative, Focused and Efficient, our company mainly serve the waste gas treatment (VOCs) Industry and metallurgical equipment of China and even whole world. We have advanced technology and rich experience in VOCs waste gas treatment project, the reference of which has been successfully applied to the industry of coating, rubber, electronic, printing, etc. We also have years of technology accumulation in the research and manufacturing of flat steel processing line, and possess nearly 100 of application example.

Our company focus on the research, design, manufacturing, installation and commissioning of VOCs organic waste gas treatment system and the revamping and updating project for energy saving and environmental protection of flat steel processing line. We can provide customers the complete solutions for environmental protection, energy saving, product quality improvement and other aspects.

We are also engaged in various spares and independent equipment for color coating line, galvanizing line, pickling line, like roller, coupler, heat exchanger, recuperator, air knife, blower, welder, tension leveler, skin pass, expansion joint, shear, jointer, stitcher, burner, radiant tube, gear motor, reducer, etc.

蓄熱式熱氧化器

Can a regenerative thermal oxidizer be retrofitted into an existing facility?

Yes, regenerative thermal oxidizers (RTOs) can be retrofitted into existing facilities under certain conditions. Retrofitting an RTO involves integrating the system into the existing infrastructure and process flow of the facility to control emissions from industrial processes. However, the feasibility of retrofitting an RTO depends on several factors related to the facility and the specific requirements of the application.

Here are some considerations for retrofitting an RTO into an existing facility:

  • Space Availability: RTOs typically require a significant amount of physical space for installation. It’s important to assess whether the facility has adequate space to accommodate the size and layout requirements of the RTO system. This includes considering the space needed for the RTO unit itself, associated ductwork, auxiliary systems, and access for maintenance.
  • Process Integration: Retrofitting an RTO involves integrating the system into the existing industrial process. This integration may require modifications to the process flow, such as rerouting ductwork, adding or modifying exhaust points, or coordinating with existing pollution control equipment. The compatibility of the RTO with the existing process and the ability to seamlessly integrate the system should be evaluated.
  • Auxiliary Systems: In addition to the RTO unit, auxiliary systems may be required for effective operation and compliance. These systems can include pre-treatment equipment such as scrubbers or filters, heat recovery units, monitoring and control systems, and stack emissions monitoring equipment. The availability of space and compatibility with existing infrastructure should be considered for accommodating these auxiliary systems.
  • Utility Requirements: RTOs have specific utility requirements, such as the need for natural gas or electricity for heating the combustion chamber and operating the control system. The availability and capacity of utilities at the existing facility should be assessed to ensure they can meet the demands of the RTO system.
  • Structural Considerations: The structural integrity of the facility should be evaluated to determine if it can support the additional weight of the RTO and associated equipment. This assessment may involve consulting with structural engineers and considering any necessary reinforcements or modifications.
  • Regulatory Compliance: Retrofitting an RTO may require obtaining permits and complying with environmental regulations. It is essential to assess the applicable regulations and ensure that the retrofit meets the necessary compliance requirements for emissions control.

It is important to consult with experienced engineering firms or RTO manufacturers who can assess the specific requirements and constraints of the facility. They can provide detailed evaluations, feasibility studies, and design recommendations for retrofitting an RTO into an existing facility. Their expertise can help ensure that the retrofit is successful, cost-effective, and compliant with environmental regulations.

蓄熱式熱氧化器

再生熱氧化器與生物過濾器的性能相比如何?

蓄熱式熱氧化器(RTO)和生物過濾器都是廣泛使用的空氣污染物處理技術,但它們的工作原理和性能特徵有所不同。以下是 RTO 和生物過濾器的性能比較:

性能方面蓄熱式熱氧化器 (RTO)生物過濾器
排放去除效率RTO 在去除揮發性有機化合物 (VOC) 和有害空氣污染物 (HAP) 方面非常有效率。他們對這些污染物的破壞效率可達 95% 以上。生物過濾器還有可能對某些揮發性有機化合物和有氣味的化合物實現高去除效率。然而,它們的性能可能會根據生物過濾器中的特定污染物和微生物活性而變化。
適用性RTO 用途廣泛,可以處理多種污染物,包括 VOC、HAP 和有味化合物。它們非常適合高流量和高污染物濃度。生物過濾器在處理有氣味的化合物和某些揮發性有機化合物方面特別有效。它們通常用於廢水處理設施、堆肥作業和農業設施等應用。
能源消耗RTO 需要大量能量才能達到並維持氧化的高工作溫度。它們依靠燃料燃燒或外部熱源來獲取所需的熱能。生物過濾器被認為是低能耗系統,因為它們依靠微生物的自然生物活性來分解污染物。它們通常不需要外部加熱或燃料消耗。
維護RTO 通常需要定期維護和監控以確保正常運作。這包括檢查、熱交換介質的清潔以及組件的潛在維修或更換。生物過濾器需要定期維護以優化其性能。這可能涉及監測和調整濕度水平、控制溫度以及偶爾更換過濾介質或添加微生物接種劑。
資本和營運成本與生物過濾器相比,RTO 由於其複雜的設計、專用材料和能源密集型操作,通常具有更高的資本成本。營運成本包括燃料消耗或暖氣用電。與 RTO 相比,生物過濾器的資本成本通常較低。它們設計更簡單,並且不需要燃料消耗。然而,營運成本可能包括定期更換過濾介質和潛在的氣味控制措施。

值得注意的是,選擇合適的技術取決於多種因素,例如待處理的特定污染物、製程條件、監管要求和特定場地的考慮因素。諮詢環境工程師或空氣污染控制專家可以幫助確定最適合特定應用的技術。

綜上所述,RTO 和生物過濾器具有不同的性能特徵,RTO 具有去除效率高、通用性強、適合高流量和高濃度應用的優點,而生物過濾器對有氣味的化合物有效,能耗低,且資本通常較低成本。

蓄熱式熱氧化器

How do regenerative thermal oxidizers handle start-up and shutdown procedures?

Regenerative thermal oxidizers (RTOs) have specific procedures for start-up and shutdown to ensure safe and efficient operation. These procedures are designed to optimize the performance of the RTO and minimize any potential risks. Here is an overview of how RTOs handle start-up and shutdown:

  • Start-up Procedure: During start-up, the RTO goes through a series of steps to reach its operating temperature. The start-up procedure typically involves the following stages:
    1. Purge Stage: The RTO is purged with clean air or an inert gas to remove any potential flammable or explosive gases that may have accumulated during the shutdown period.
    2. Preheat Stage: The RTO’s heat exchangers are preheated using a burner or an auxiliary heat source. This gradually increases the temperature of the heat exchange media (typically ceramic or metallic beds) and the combustion chamber.
    3. Heat Soak Stage: Once the heat exchangers reach a certain temperature, the RTO enters the heat soak stage. In this stage, the heat exchangers are fully heated, and the RTO operates in a self-sustaining mode, with the combustion chamber temperature being maintained primarily by the heat released from the oxidation of pollutants in the exhaust gas.
    4. Normal Operation: After the heat soak stage, the RTO is considered to be in normal operation mode, where it maintains the desired operating temperature and treats the exhaust gas containing pollutants.
  • Shutdown Procedure: The shutdown procedure of an RTO is aimed at safely and efficiently stopping the operation of the system. The procedure typically involves the following steps:
    1. Cool Down: The RTO is gradually cooled down by reducing the flow of the exhaust gas and the supply of combustion air. This helps to prevent thermal stress on the equipment and minimize the risk of fires or other safety hazards.
    2. 熱回收: During the cool-down phase, the RTO may employ heat recovery techniques to capture and utilize the residual heat for other purposes, such as preheating incoming process air or water.
    3. Purge: Once the RTO has cooled down sufficiently, a purge cycle is initiated to remove any residual gases or contaminants from the system. This helps to ensure a clean and safe environment for maintenance activities or subsequent start-ups.
    4. Complete Shutdown: After the purge cycle, the RTO is considered to be in a fully shut-down state, and it can remain in this state until the next start-up is initiated.

It is important to note that the specific start-up and shutdown procedures for an RTO may vary depending on the design and manufacturer. Manufacturers typically provide detailed guidelines and instructions for operating their specific RTO models, and it is crucial to follow these guidelines to ensure safe and efficient operation.

China high quality Regenerative/Recuperative Thermal Oxidizer (RTO)
editor by CX 2024-04-10