Basic Info.
Model NO.
Amazing RTO
유형
Incinerator
Low Maintenance
100
Easy Operation
100
Energy Saving
100
High Efficiency
100
Trademark
Bjamazing
Transport Package
Overseas
Specification
111
Origin
China
HS Code
2221111
Product Description
RTO
재생 열 산화 장치
Compared with traditional catalytic combustion, direct thermal oxidizer, RTO has the merits of high heating efficiency, low operation cost, and the ability to treat large flux low concentration waste gas. When VOCs concentration is high, secondary heat recycle can be realized, which will greatly reduce the operation cost. Because RTO can preheat the waste gas by levels through ceramic heat accumulator, which could make the waste gas to be completely heated and cracked with no dead corner(treatment efficiency>99%),which reduce the NOX in the Exhausting gas, if the VOC density >1500mg/Nm3, when the waste gas reach cracking area, it has been heated up to cracking temperature by heat accumulator, the burner will be closed under this condition.
RTO can be devided into chamber type and rotary type according to difference operation mode. Rotary type RTO has advantages in system pressure, temperature stability, investment amount, etc
RTO types | Efficiency | Pressure change (mmAq) | Size | (max)Treatment volume | |
Treatment efficiency | Heat recycle efficiency | ||||
Rotary type RTO | 99 % | 97 % | 0-4 | small (1 time) | 50000Nm3/h |
Three chamber type RTO | 99 % | 97 % | 0-10 | Large (1.5times) | 100000Nm3/h |
Two chamber type RTO | 95 % | 95 % | 0-20 | middle (1.2times) | 100000Nm3/h |
Regenerative Thermal Oxidizer, Regenerative Thermal Oxidizer, Regenerative Thermal Oxidizer, Thermal Oxidizer, Thermal Oxidizer, Thermal Oxidizer, oxidizer, oxidizer, oxidizer, incinerator, incinerator, incinerator, waste gas treatment, waste gas treatment, waste gas treatment, VOC treatment, VOC treatment, VOC treatment, RTO, RTO, RTO, Rotary RTO, Rotary RTO, Rotary RTO, Chamber RTO, Chamber RTO, Chamber RTO
Address: 8 floor, E1, Pinwei building, Dishengxi road, Yizhuang, ZheJiang , China
Business Type: Manufacturer/Factory, Trading Company
Business Range: Electrical & Electronics, Industrial Equipment & Components, Manufacturing & Processing Machinery, Metallurgy, Mineral & Energy
Management System Certification: ISO 9001, ISO 14001
Main Products: Rto, Color Coating Line, Galvanizing Line, Air Knife, Spares for Processing Line, Coater, Independent Equipments, Sink Roll, Revamping Project, Blower
Company Introduction: ZheJiang Amazing Science & Technology Co., Ltd is a thriving Hi-tech company, located in ZheJiang Economic and Technological Development Area(BDA). Adhering to the concept of Realistic, Innovative, Focused and Efficient, our company mainly serve the waste gas treatment (VOCs) Industry and metallurgical equipment of China and even whole world. We have advanced technology and rich experience in VOCs waste gas treatment project, the reference of which has been successfully applied to the industry of coating, rubber, electronic, printing, etc. We also have years of technology accumulation in the research and manufacturing of flat steel processing line, and possess nearly 100 of application example.
Our company focus on the research, design, manufacturing, installation and commissioning of VOCs organic waste gas treatment system and the revamping and updating project for energy saving and environmental protection of flat steel processing line. We can provide customers the complete solutions for environmental protection, energy saving, product quality improvement and other aspects.
We are also engaged in various spares and independent equipment for color coating line, galvanizing line, pickling line, like roller, coupler, heat exchanger, recuperator, air knife, blower, welder, tension leveler, skin pass, expansion joint, shear, jointer, stitcher, burner, radiant tube, gear motor, reducer, etc.
Can regenerative thermal oxidizers be used for odor control in sewage treatment plants?
Regenerative thermal oxidizers (RTOs) are not commonly used for odor control in sewage treatment plants. While RTOs are effective in controlling gaseous pollutants, their application for odor control in wastewater treatment facilities has certain limitations and considerations.
Here are some key points to consider regarding the use of RTOs for odor control in sewage treatment plants:
- Nature of Odorous Compounds: Odors in sewage treatment plants are primarily caused by volatile organic compounds (VOCs) and sulfur compounds released during the treatment processes. RTOs are effective in treating VOCs, but they may not be specifically designed to address sulfur compounds, which can be challenging to control through thermal oxidation.
- Operating Temperature: RTOs require high operating temperatures for efficient pollutant destruction. However, the presence of sulfur compounds in sewage treatment plant emissions can lead to corrosion and fouling at elevated temperatures, potentially impacting the performance and lifespan of the RTO system.
- Complex Odor Mixture: Odors in sewage treatment plants are often complex mixtures of various compounds. RTOs are generally designed to treat specific target pollutants and may not be optimized for the treatment of the wide range of compounds present in sewage plant odors. A comprehensive odor control strategy typically involves multiple treatment techniques tailored to the specific odor profile.
- Alternative Odor Control Technologies: Sewage treatment plants typically employ a combination of dedicated odor control technologies such as biofilters, activated carbon adsorption systems, chemical scrubbers, or other specialized methods. These technologies are specifically designed for the removal of odorous compounds and are often more suitable and efficient for odor control in wastewater treatment facilities.
- Compliance with Regulations: Odor emissions from sewage treatment plants are subject to regulatory requirements and local community sensitivities. Sewage treatment facilities need to comply with applicable regulations and implement effective odor control measures that are proven to be efficient in mitigating the specific odor issues associated with their operations.
In summary, while RTOs are effective for controlling gaseous pollutants, they are not commonly used as the primary odor control technology in sewage treatment plants. Sewage treatment facilities typically employ dedicated odor control technologies that are specifically designed for the removal of odorous compounds and can provide optimal performance and compliance with odor regulations.
What are the startup and shutdown time requirements for a regenerative thermal oxidizer?
The startup and shutdown time requirements for a regenerative thermal oxidizer (RTO) can vary depending on several factors, including the specific design of the RTO, the size of the system, and the operating conditions. Here are some key points regarding the startup and shutdown time requirements for an RTO:
- Startup Time: The startup time for an RTO typically refers to the time it takes for the system to reach its operating temperature and stabilize for effective emission control. The startup time can range from several hours to several days, depending on the size of the RTO, the thermal capacity of the heat exchange media, and the desired operating temperature. During startup, the RTO gradually heats up the heat exchange beds or media using a burner system or other heating mechanisms until the desired temperature is reached.
- Shutdown Time: The shutdown time for an RTO refers to the time it takes to safely cool down the system and bring it to a complete stop. The shutdown time can also vary and may range from several hours to several days. During shutdown, the flow of exhaust gas is stopped, and the RTO initiates a cooling process to lower the temperature of the heat exchange media. Cooling mechanisms such as air or water may be used to expedite the cooling process and ensure safe operation.
- System Requirements: The specific startup and shutdown time requirements for an RTO are often determined by the process requirements, operational needs, and regulatory compliance. Some applications may require faster startup and shutdown times to accommodate frequent process changes, while others may prioritize energy efficiency and opt for longer startup and shutdown times to allow for heat recovery and minimize fuel consumption.
- Control Systems: Advanced control systems are typically employed to monitor and control the startup and shutdown processes of an RTO. These systems ensure that the temperature ramp-up and ramp-down rates are within safe limits and that the system operates efficiently and reliably during these phases.
It is essential to consult with RTO manufacturers or experienced engineers to determine the specific startup and shutdown time requirements for a particular RTO based on its design, size, and intended application. They can provide guidance on optimizing the startup and shutdown processes to meet the operational and regulatory needs while ensuring the safe and efficient operation of the RTO.
In summary, the startup and shutdown time requirements for an RTO can vary depending on factors such as system design, size, and operational considerations. Startup times can range from hours to days, while shutdown times can also vary. These requirements are tailored to meet the specific needs of the process and ensure effective emission control while maintaining operational safety.
Can regenerative thermal oxidizers reduce odor emissions?
Regenerative thermal oxidizers (RTOs) are effective in reducing odor emissions from industrial processes. While their primary purpose is to control and destroy volatile organic compounds (VOCs) and hazardous air pollutants (HAPs), they can also effectively mitigate odorous compounds.
Here’s how RTOs contribute to odor reduction:
- Oxidation of Odorous Compounds: RTOs operate at high temperatures, typically ranging from 1,400 to 1,800 degrees Fahrenheit (760 to 980 degrees Celsius). These elevated temperatures facilitate the complete oxidation of odorous compounds, breaking them down into harmless byproducts, such as carbon dioxide and water vapor. The thermal oxidation process ensures the destruction of odor-causing molecules.
- High Destruction Efficiency: RTOs are designed to achieve high destruction efficiencies, often exceeding 99%. This means that the vast majority of odorous compounds are effectively eliminated during the combustion process, resulting in a significant reduction in odor emissions.
- Retention Time: RTOs provide a sufficiently long retention time for the exhaust gases within the combustion chamber. This allows for thorough mixing and residence time necessary for the complete oxidation of odorous compounds. The extended contact time ensures that the odorous molecules have sufficient exposure to the high temperatures, resulting in their destruction.
- Control of VOCs: Many odorous compounds are also VOCs. By effectively controlling and destroying VOC emissions, RTOs indirectly reduce odor emissions as well. The comprehensive destruction of VOCs prevents their release into the atmosphere, thereby minimizing the associated odors.
- Monitoring and Optimization: Proper monitoring and optimization of RTO operation can further enhance odor reduction. By continuously monitoring the process parameters, such as temperature, airflow, and pollutant concentrations, adjustments can be made to optimize the performance of the RTO and ensure effective odor control.
It’s important to note that while RTOs are effective in reducing odor emissions, the specific odor compounds and their concentrations in the exhaust stream can influence the overall odor control efficiency. Additionally, proper design, operation, and maintenance of the RTO are crucial for achieving optimal odor reduction.
editor by CX 2023-09-06