Základní informace.
Material
Cordierite
Aplikace
Industry, Food and Beverage, Medicine, Textile, Metallurgy
Typ
Ceramic Filter
Filter Connector
Flat Connector
Filtration Grade
ULPA Filter
Activated Carbon Filter Type
Bulk Type
Ochranná známka
SW
Přepravní balíček
Carton
Specifikace
50x50x50, 100x100x50, 595x260x95
Původ
Čína
Kód HS
3815120090
Popis produktu
Description:;
Carrier:; Ceramic honeycomb substrate (cordierite monolith); or metal honeycomb substrate (stainless steel crust and Fe-Cr-Al honeycomb body);.;
Technical Data:;
Material:;Cordierite,; mullite ceramics
Size:;
50x50x50,;100x100x50,;595x260x95
Working Temperature:;220°C-1100°C
Channels:;Circular,; Square,; Rectangle
Cell Density:;
50-400 CPSI
Type:; Catalytic Converter
Usage:;
Catalytic Converter
Application:;Enameled wire,; paint room,; waste gas treatment industry.;
——————————————————————————————————————————————————
Regenerative Thermal/Catalytic Oxidizer (RTO/RCO); :;
Regenerated heat/catalytic oxidant (RTO/RCO);:; it is widely used in automotive coatings,; chemical industry,; electronic and electric manufacturing industry,; contact combustion system and other fields.;Ceramic honeycomb is designated as a structural regenerative medium for RTO/RCO.;
Advantage:;
1.; Various materials and specifications
2.; Products with different formulas can be customized according to customer requirements.;
3.; Small resistance loss
4.; Low thermal expansion coefficient
5.; Excellent crack resistance
6.; It can be customized to meet the emission standards of different countries.;
Aplikace:;
1.; It can be used as a heat exchanger in the RTO of the heat recovery device.;
2.; Can be used as a catalyst to purify automobile exhaust and motorcycle exhaust to remove odor.;
3.; Applicable to food service industry,; environmental protection industry,; metallurgy industry,; etc
Test Equipment:;
Particle size distribution tester
Aperture and specific surface meter
Metal distribution,; crystalline structure
Catalyst activity evaluation system
Production Equipment:;
Coating continuous microwave drying system
Slurry nanometer grinding preparation system
Slurry quantitative spraying system
RFQ:;
Q:;Are you a trading company or a manufacturer?
A:;We are professional manufacturer which has almost 20 years of experience in this industry.;
Q:;Can you produce according to the samples?
A:;Yes,;we can produce by your samples or technical drawings.;
Q:;Would it be possible for us to visit your factory?
A:;Sure,;we welcomed our customers visit our factory in any time.;
Q:;Will your company supply samples?
A:;Yes,;the sample expense will be deducted from the value of your order.;
Q:;What’s your payment terms?
A:;T/T,; L/C,; Western Union,; Money Gram,; are available for us.;
Q:;Delivery time for my order?
A:;Within 7-15 working days for your sample order; 20 working days for your bulk order( It depends on the models and quantity you are going to order);.;
Address: Room. 3902-2 TianAn CHINAMFG Town No. 228 Ling Lake Avenue, New Wu District, HangZhou City, ZheJiang Province, China.
Business Type: Manufacturer/Factory, Group Corporation
Business Range: Auto, Motorcycle Parts & Accessories, Chemicals, Industrial Equipment & Components, Manufacturing & Processing Machinery
Management System Certification: ISO 9001, ISO 14001, ISO 20000, IATF16949
Main Products: Honeycomb Catalytic, Three Way Catalytic, Chemical Catalytic, Exhaust Filter, Industrial Catalytic
Company Introduction: Established in 2003, Sheung Well International Corp. Is a professional enterprise specialized in developing, manufacturing, selling automotive vehicles, Universal fuel engine and industrial three-way catalyst and converters, four-way converters. With independent intellectual property rights, its technology has been approved by ISO9001, TS16949 quality and management systems.
Sheung Well is an all-round designer and manufacturer who has a innovative and quality managing team mainly consists of doctorates and masters. Based on its cutting edge technology, rich experience and modern production and quality management skills, CHINAMFG is providing customers with first-class products and services.
Oriented in market, with innovation as its soul, centralized in serving the society, CHINAMFG lays emphasis on developing technology and products of controlling Exhaust emissions and other industrial catalysts. By providing customers with technology and supports of new products, it is committed to becoming the word-class all-around enterprise in catalyst circle from home and abroad.
Can a regenerative thermal oxidizer be retrofitted into an existing facility?
Yes, regenerative thermal oxidizers (RTOs) can be retrofitted into existing facilities under certain conditions. Retrofitting an RTO involves integrating the system into the existing infrastructure and process flow of the facility to control emissions from industrial processes. However, the feasibility of retrofitting an RTO depends on several factors related to the facility and the specific requirements of the application.
Here are some considerations for retrofitting an RTO into an existing facility:
- Space Availability: RTOs typically require a significant amount of physical space for installation. It’s important to assess whether the facility has adequate space to accommodate the size and layout requirements of the RTO system. This includes considering the space needed for the RTO unit itself, associated ductwork, auxiliary systems, and access for maintenance.
- Process Integration: Retrofitting an RTO involves integrating the system into the existing industrial process. This integration may require modifications to the process flow, such as rerouting ductwork, adding or modifying exhaust points, or coordinating with existing pollution control equipment. The compatibility of the RTO with the existing process and the ability to seamlessly integrate the system should be evaluated.
- Auxiliary Systems: In addition to the RTO unit, auxiliary systems may be required for effective operation and compliance. These systems can include pre-treatment equipment such as scrubbers or filters, heat recovery units, monitoring and control systems, and stack emissions monitoring equipment. The availability of space and compatibility with existing infrastructure should be considered for accommodating these auxiliary systems.
- Utility Requirements: RTOs have specific utility requirements, such as the need for natural gas or electricity for heating the combustion chamber and operating the control system. The availability and capacity of utilities at the existing facility should be assessed to ensure they can meet the demands of the RTO system.
- Structural Considerations: The structural integrity of the facility should be evaluated to determine if it can support the additional weight of the RTO and associated equipment. This assessment may involve consulting with structural engineers and considering any necessary reinforcements or modifications.
- Regulatory Compliance: Retrofitting an RTO may require obtaining permits and complying with environmental regulations. It is essential to assess the applicable regulations and ensure that the retrofit meets the necessary compliance requirements for emissions control.
It is important to consult with experienced engineering firms or RTO manufacturers who can assess the specific requirements and constraints of the facility. They can provide detailed evaluations, feasibility studies, and design recommendations for retrofitting an RTO into an existing facility. Their expertise can help ensure that the retrofit is successful, cost-effective, and compliant with environmental regulations.
Can regenerative thermal oxidizers be used for treating emissions from pharmaceutical processes?
Yes, regenerative thermal oxidizers (RTOs) can be effectively used for treating emissions from pharmaceutical processes. Pharmaceutical manufacturing processes often generate volatile organic compounds (VOCs) and hazardous air pollutants (HAPs) that need to be controlled to comply with environmental regulations and ensure air quality. Here are some key points regarding the use of RTOs for treating emissions from pharmaceutical processes:
- Kontrola emisí: RTO jsou navrženy tak, aby dosahovaly vysoké účinnosti ničení VOC a HAP. Tyto znečišťující látky se oxidují v RTO při vysokých teplotách, typicky nad účinností 95%, a přeměňují je na oxid uhličitý (CO2) and water vapor. This ensures effective control and reduction of emissions from pharmaceutical processes.
- Kompatibilita procesu: RTOs can be integrated into the exhaust systems of various pharmaceutical processes, capturing and treating the emissions before they are released into the atmosphere. The RTO is typically connected to the process equipment or exhaust stack, allowing the VOC-laden air to pass through the oxidizer for treatment.
- Flexibilita: RTOs offer flexibility in handling a wide range of operating conditions and pollutants. Pharmaceutical processes can vary in terms of flow rates, temperature, and composition of emissions. RTOs are designed to accommodate these variations and provide effective treatment even under fluctuating conditions.
- Rekuperace tepla: RTO obsahují systémy výměny tepla, které umožňují rekuperaci a opětovné využití tepelné energie. Výměníky tepla v RTO zachycují teplo z odcházejících výfukových plynů a předávají je do vstupního procesního vzduchu nebo proudu plynu. Tento proces rekuperace tepla zlepšuje celkovou energetickou účinnost systému a snižuje potřebu dodatečné spotřeby paliva.
- Dodržování předpisů: Pharmaceutical processes are subject to regulatory requirements for air quality and emissions control. RTOs are capable of achieving the necessary destruction efficiencies and can help pharmaceutical manufacturers comply with environmental regulations. The use of RTOs demonstrates a commitment to sustainable practices and responsible management of air emissions.
It is important to note that the specific design and configuration of the RTO, as well as the characteristics of the pharmaceutical emissions, should be considered when implementing an RTO for a specific application. Consulting with experienced engineers or RTO manufacturers can provide valuable insights into the proper sizing, integration, and performance requirements for treating emissions from pharmaceutical processes.
In summary, RTOs are a suitable and effective technology for treating emissions from pharmaceutical processes, providing high destruction efficiencies, compatibility with various processes, flexibility in handling operating conditions, heat recovery, and compliance with environmental regulations.
How do regenerative thermal oxidizers handle start-up and shutdown procedures?
Regenerative thermal oxidizers (RTOs) have specific procedures for start-up and shutdown to ensure safe and efficient operation. These procedures are designed to optimize the performance of the RTO and minimize any potential risks. Here is an overview of how RTOs handle start-up and shutdown:
- Start-up Procedure: During start-up, the RTO goes through a series of steps to reach its operating temperature. The start-up procedure typically involves the following stages:
- Purge Stage: The RTO is purged with clean air or an inert gas to remove any potential flammable or explosive gases that may have accumulated during the shutdown period.
- Preheat Stage: The RTO’s heat exchangers are preheated using a burner or an auxiliary heat source. This gradually increases the temperature of the heat exchange media (typically ceramic or metallic beds) and the combustion chamber.
- Heat Soak Stage: Once the heat exchangers reach a certain temperature, the RTO enters the heat soak stage. In this stage, the heat exchangers are fully heated, and the RTO operates in a self-sustaining mode, with the combustion chamber temperature being maintained primarily by the heat released from the oxidation of pollutants in the exhaust gas.
- Normal Operation: After the heat soak stage, the RTO is considered to be in normal operation mode, where it maintains the desired operating temperature and treats the exhaust gas containing pollutants.
- Shutdown Procedure: The shutdown procedure of an RTO is aimed at safely and efficiently stopping the operation of the system. The procedure typically involves the following steps:
- Cool Down: The RTO is gradually cooled down by reducing the flow of the exhaust gas and the supply of combustion air. This helps to prevent thermal stress on the equipment and minimize the risk of fires or other safety hazards.
- Rekuperace tepla: During the cool-down phase, the RTO may employ heat recovery techniques to capture and utilize the residual heat for other purposes, such as preheating incoming process air or water.
- Purge: Once the RTO has cooled down sufficiently, a purge cycle is initiated to remove any residual gases or contaminants from the system. This helps to ensure a clean and safe environment for maintenance activities or subsequent start-ups.
- Complete Shutdown: After the purge cycle, the RTO is considered to be in a fully shut-down state, and it can remain in this state until the next start-up is initiated.
It is important to note that the specific start-up and shutdown procedures for an RTO may vary depending on the design and manufacturer. Manufacturers typically provide detailed guidelines and instructions for operating their specific RTO models, and it is crucial to follow these guidelines to ensure safe and efficient operation.
editor by CX 2024-02-18