Yandex Metrika

Maklumat Asas.

Model NO.

RTO yang menakjubkan

taip

Insinerator

Kecekapan Tinggi

100

Penjimatan Tenaga

100

Penyelenggaraan Rendah

100

Operasi Mudah

100

Tanda dagangan

Bjamazing

Pakej Pengangkutan

Luar negara

Spesifikasi

111

asal usul

China

Kod HS

2221111

Penerangan Produk

RTO

Pengoksida Terma Penjanaan Semula

Berbanding dengan pembakaran pemangkin tradisional,; pengoksida haba langsung,; RTO mempunyai merit kecekapan pemanasan yang tinggi,; kos operasi yang rendah,; dan keupayaan untuk merawat gas buangan kepekatan rendah fluks besar.; Apabila kepekatan VOC tinggi,; kitar semula haba sekunder boleh direalisasikan,; yang akan mengurangkan kos operasi.; Kerana RTO boleh memanaskan gas sisa mengikut tahap melalui penumpuk haba seramik,; yang boleh membuat gas buangan dipanaskan sepenuhnya dan retak tanpa sudut mati (kecekapan rawatan> 99%);,; yang mengurangkan NOX dalam gas yang meletihkan,; jika ketumpatan VOC >1500mg/Nm3,; apabila gas buangan mencapai kawasan retak,; ia telah dipanaskan sehingga suhu retak oleh penumpuk haba,; penunu akan ditutup di bawah keadaan ini.;

RTO boleh dibahagikan kepada jenis ruang dan jenis berputar mengikut mod operasi perbezaan.; RTO jenis Rotary mempunyai kelebihan dalam tekanan sistem,; kestabilan suhu,; jumlah pelaburan,; dll

jenis RTO  KecekapanPerubahan tekanan
(mmAq);
Saiz(maks); volum rawatan  
 
Kecekapan rawatan Kecekapan kitar semula haba  
RTO jenis putar99%97%0-4kecil
(1 kali);
50000Nm3/j  
RTO jenis tiga ruang99%97%  0-10besar
(1.;5kali);
100000Nm3/j
RTO jenis dua ruang95%95%0-20tengah
(1.;2kali);
100000Nm3/j  

Pengoksida Terma Penjanaan Semula,; Pengoksida Terma Penjanaan Semula,; Pengoksida Terma Penjanaan Semula,; Pengoksida Terma,; Pengoksida Terma,; Pengoksida Terma,; pengoksida,; pengoksida,; pengoksida,; insinerator,; insinerator,; insinerator,; rawatan gas buangan,; rawatan gas buangan,; rawatan gas buangan,; rawatan VOC,; rawatan VOC,; rawatan VOC,; RTO,; RTO,; RTO,; Rotary RTO,; Rotary RTO,; Rotary RTO,; RTO Dewan,; RTO Dewan,; RTO Dewan

Alamat: tingkat 8, E1, bangunan Pinwei, jalan Dishengxi, Yizhuang, ZheJiang, China

Jenis Perniagaan: Pengeluar/Kilang, Syarikat Perdagangan

Julat Perniagaan: Elektrik & Elektronik, Peralatan & Komponen Industri, Jentera Pembuatan & Pemprosesan, Metalurgi, Mineral & Tenaga

Pensijilan Sistem Pengurusan: ISO 9001, ISO 14001

Produk Utama: Rto, Talian Salutan Warna, Talian Galvanisasi, Pisau Udara, Alat Ganti untuk Talian Pemprosesan, Coater, Peralatan Bebas, Gulung Sink, Projek Ubahsuai, Blower

Pengenalan Syarikat: ZheJiang Amazing Science & Technology Co., Ltd ialah sebuah syarikat berteknologi tinggi yang berkembang maju, terletak di ZheJiang Economic and Technological Development Area(BDA). Berpegang kepada konsep Realistik, Inovatif, Fokus dan Cekap, syarikat kami menyediakan perkhidmatan terutamanya dalam industri rawatan gas sisa (VOC) dan peralatan metalurgi China dan juga seluruh dunia. Kami mempunyai teknologi canggih dan pengalaman yang kaya dalam projek rawatan gas buangan VOC, yang rujukannya telah berjaya digunakan untuk industri salutan, getah, elektronik, percetakan, dll. Kami juga mempunyai pengumpulan teknologi selama bertahun-tahun dalam penyelidikan dan pembuatan flat talian pemprosesan keluli, dan mempunyai hampir 100 contoh aplikasi.

Syarikat kami menumpukan pada penyelidikan, reka bentuk, pengilangan, pemasangan dan pentauliahan sistem rawatan gas sisa organik VOC dan projek merombak dan mengemas kini untuk penjimatan tenaga dan perlindungan alam sekitar barisan pemprosesan keluli rata. Kami boleh menyediakan pelanggan penyelesaian lengkap untuk perlindungan alam sekitar, penjimatan tenaga, peningkatan kualiti produk dan aspek lain.

Kami juga terlibat dalam pelbagai alat ganti dan peralatan bebas untuk garis salutan warna, garis galvanizing, garis penjerukan, seperti penggelek, pengganding, penukar haba, recuperator, pisau udara, peniup, pengimpal, penyamara ketegangan, pas kulit, sambungan pengembangan, ricih, penyambung , penjahit, penunu, tiub berseri, motor gear, pengurang, dsb.

pengoksida terma regeneratif

Can regenerative thermal oxidizers be used for abating hazardous air pollutants (HAPs)?

Yes, regenerative thermal oxidizers (RTOs) can be used effectively for abating hazardous air pollutants (HAPs). RTOs are widely recognized and employed as one of the most efficient and reliable technologies for the destruction of a wide range of volatile organic compounds (VOCs) and hazardous air pollutants.

Here are some key points regarding the use of RTOs for abating HAPs:

  • High Destruction Efficiency: RTOs are known for their high destruction efficiency, which refers to their ability to effectively oxidize and destroy HAPs. The combustion chamber within the RTO is designed to maintain a sufficiently high temperature (typically above 1,400°F or 760°C) to ensure complete oxidation of the pollutants, including HAPs.
  • Wide Applicability: RTOs can handle a wide range of HAPs and VOCs, including but not limited to benzene, toluene, xylene, chlorinated compounds, formaldehyde, and various other organic pollutants. Their versatility makes them suitable for diverse industrial applications where HAPs may be present.
  • Retention Time: RTOs are designed with a sufficient residence or retention time within the combustion chamber. This allows the exhaust gases containing HAPs to spend enough time in the high-temperature zone, ensuring that HAPs are adequately treated and oxidized to harmless byproducts.
  • Pemulihan Haba: The heat recovery system in an RTO, typically using ceramic media beds or heat exchangers, plays a crucial role in the destruction of HAPs. The heat recovery system helps maintain the required temperature and provides thermal energy to sustain the combustion process, ensuring effective destruction of HAPs even during variable operating conditions.
  • Pematuhan dengan Peraturan: RTOs are designed to meet stringent environmental regulations governing HAP emissions. By effectively destroying HAPs, RTOs help industries comply with air quality standards and emission limits set by regulatory agencies.
  • Monitoring and Controls: RTOs are equipped with advanced monitoring and control systems that continuously monitor parameters such as temperature, pressure, and pollutant concentrations. These systems ensure the optimal performance of the RTO in treating HAPs and allow for adjustments and optimization as needed.

It’s important to note that the specific design and configuration of an RTO may need to be tailored to the characteristics of the HAPs being treated. Factors such as the HAPs’ chemical composition, concentration, and other process-specific considerations may influence the selection and customization of the RTO system.

In summary, RTOs are highly effective and reliable technologies for abating hazardous air pollutants. Their high destruction efficiency, wide applicability, and compliance with regulations make them a preferred choice for industries seeking to mitigate the environmental impact of HAP emissions.

pengoksida terma regeneratif

How do regenerative thermal oxidizers handle variations in pollutant composition?

Regenerative thermal oxidizers (RTOs) are designed to handle variations in pollutant composition effectively. RTOs are commonly used for treating volatile organic compounds (VOCs) and hazardous air pollutants (HAPs) emitted from various industrial processes. Here are some key points regarding how RTOs handle variations in pollutant composition:

  • Thermal Oxidation Process: RTOs utilize a thermal oxidation process to eliminate pollutants. The process involves raising the temperature of the exhaust gas to a level where the pollutants react with oxygen and are oxidized to carbon dioxide (CO2) and water vapor. This high-temperature oxidation process is effective in treating a wide range of pollutants, regardless of their specific composition.
  • Wide Range of Pollutant Compatibility: RTOs are designed to handle a broad spectrum of pollutants, including VOCs and HAPs with varying chemical compositions. The high operating temperatures in the RTO, typically between 1400°F to 1600°F (760°C to 870°C), ensure that a wide range of organic compounds can be effectively oxidized, regardless of their molecular structure or chemical makeup.
  • Residence Time and Dwell Time: RTOs provide sufficient residence time and dwell time for the exhaust gas within the oxidizer. The exhaust gas is directed through a heat exchange system, where it passes through ceramic media beds or heat exchange media. These media beds absorb the heat from the high-temperature combustion chamber and transfer it to the incoming exhaust gas. The extended residence time and dwell time ensure that even complex or less reactive pollutants have enough contact time with the elevated temperature to be effectively oxidized.
  • Pemulihan Haba: RTOs incorporate heat recovery systems that maximize thermal efficiency. The heat exchangers within the RTO capture and transfer heat from the outgoing exhaust gas to the incoming process stream. This heat exchange process helps maintain the high operating temperatures required for effective pollutant destruction while minimizing the energy consumption of the system. The ability to recover and reuse heat also contributes to the RTO’s ability to handle variations in pollutant composition.
  • Advanced Control Systems: RTOs employ advanced control systems to monitor and optimize the oxidation process. These control systems continuously monitor parameters such as temperature, flow rates, and pollutant concentrations. By adjusting the operating conditions in response to variations in pollutant composition, the control systems ensure optimal performance and maintain high destruction efficiencies.

In summary, RTOs handle variations in pollutant composition by utilizing a thermal oxidation process, accommodating a wide range of pollutants, providing sufficient residence time and dwell time, incorporating heat recovery systems, and employing advanced control systems. These features allow RTOs to effectively treat emissions with different pollutant compositions, ensuring high destruction efficiencies and compliance with environmental regulations.

pengoksida terma regeneratif

Can regenerative thermal oxidizers reduce odor emissions?

Regenerative thermal oxidizers (RTOs) are effective in reducing odor emissions from industrial processes. While their primary purpose is to control and destroy volatile organic compounds (VOCs) and hazardous air pollutants (HAPs), they can also effectively mitigate odorous compounds.

Here’s how RTOs contribute to odor reduction:

  • Oxidation of Odorous Compounds: RTOs operate at high temperatures, typically ranging from 1,400 to 1,800 degrees Fahrenheit (760 to 980 degrees Celsius). These elevated temperatures facilitate the complete oxidation of odorous compounds, breaking them down into harmless byproducts, such as carbon dioxide and water vapor. The thermal oxidation process ensures the destruction of odor-causing molecules.
  • High Destruction Efficiency: RTOs are designed to achieve high destruction efficiencies, often exceeding 99%. This means that the vast majority of odorous compounds are effectively eliminated during the combustion process, resulting in a significant reduction in odor emissions.
  • Retention Time: RTOs provide a sufficiently long retention time for the exhaust gases within the combustion chamber. This allows for thorough mixing and residence time necessary for the complete oxidation of odorous compounds. The extended contact time ensures that the odorous molecules have sufficient exposure to the high temperatures, resulting in their destruction.
  • Control of VOCs: Many odorous compounds are also VOCs. By effectively controlling and destroying VOC emissions, RTOs indirectly reduce odor emissions as well. The comprehensive destruction of VOCs prevents their release into the atmosphere, thereby minimizing the associated odors.
  • Monitoring and Optimization: Proper monitoring and optimization of RTO operation can further enhance odor reduction. By continuously monitoring the process parameters, such as temperature, airflow, and pollutant concentrations, adjustments can be made to optimize the performance of the RTO and ensure effective odor control.

It’s important to note that while RTOs are effective in reducing odor emissions, the specific odor compounds and their concentrations in the exhaust stream can influence the overall odor control efficiency. Additionally, proper design, operation, and maintenance of the RTO are crucial for achieving optimal odor reduction.

China factory Rto Bed Type/Chamber Type Rto Regenerative Thermal Oxidizer
editor oleh CX 2024-04-04