Maklumat Asas.
Model NO.
RTO
taip
Instrumen Pemantauan Alam Sekitar
Fungsi Utama
Penyingkiran Gas Sisa
Permohonan
Industri Kimia
Jenama
Raidsant
Kecekapan Bersih
99.8%
keadaan
baru
Tanda dagangan
Raidsant
Pakej Pengangkutan
Filem Dibalut
asal usul
ZheJiang China
Penerangan Produk
HangZhou Raidsant Machinery Co.;,; Ltd.; mengambil jurusan dalam membangunkan dan mengeluarkan mesin pelletizing penyejuk serbuk inovatif dan mesin rawatan gas sisa industri yang berkaitan.; Dengan sejarah pengeluaran hampir 20 tahun,; kami mempunyai pasaran yang baik di lebih daripada 20 wilayah di China,; dan beberapa produk kami telah dieksport ke Arab Saudi, Singapura, Mexico,; Brazil,;Sepanyol,; Amerika,; Rusia dan Korea,; dan lain-lain;
Spesifikasi:;
* Lebih padat daripada kemudahan sedia ada
* Kos operasi rendah
* Jangka hayat kemudahan yang panjang
* Tiada perubahan tekanan
Tujuan:;
Sistem penjimatan tenaga yang membakar sebatian organik meruap (VOC); dan sisa gas dengan menggunakan haba,; dan ia mengumpul lebih 99.;8% haba buangan gas ekzos dengan menggunakan bahan penjana semula seramik (mangkin); dengan luas permukaan yang besar dan kehilangan tekanan rendah.;
Permohonan:;
1.; Proses pengeringan mengecat
2.; proses percetakan logam
3.; proses pengeringan gentian
4.; proses pita pelekat
5.; proses rawatan sisa
6.; proses pembuatan semikonduktor
7.; asap,; proses kuih-muih dan membakar
8.; proses petrokimia,;
9.; proses pembuatan ubat dan makanan,;
10.; proses penjanaan VOC yang lain
Kelebihan:;
* Lebih padat daripada kemudahan sedia ada
* Tiada perubahan tekanan
* Kadar pemulihan haba tinggi (lebih 95%);
* Rawatan VOC yang sempurna (lebih 99.;8%);
* Jangka hayat kemudahan yang panjang
* Kos operasi rendah
* Boleh dibuat dalam bulatan atau segi empat
Penerangan Umum dan Ciri:;
1.; Prinsip operasi
Kaedah pengendalian yang menukar nyahcas secara berterusan dengan memutarkan Injap Putar
2.; Perubahan Tekanan Proses
Tiada perubahan tekanan kerana arah angin berubah mengikut susunan mengikut putaran Injap Putar
3.; Kos Pelaburan
Sekitar 70% daripada Jenis Katil
4.; Ruang Pemasangan
Ia adalah kapal tunggal jadi ia padat dan memerlukan ruang pemasangan yang kurang.;
5.; Penyelenggaraan
Mudah untuk menyelenggaranya kerana Rotary Valve adalah satu-satunya 1 bahagian yang bergerak.;
Bahagian pengedap Rotary Valve jarang haus kerana ia berputar pada kelajuan rendah.;
6.; Kestabilan
Tiada risiko dalam proses kerana ia sentiasa dibuka walaupun Rotary Valve menghadapi masalah.;
7.; Kecekapan Rawatan
Kecekapan rawatan dikekalkan kerana bahagian pengedap jarang haus walaupun ia dikendalikan untuk masa yang lama.;
Alamat: No.3, Jalan Tengah Zhenxin, Zon Pembangunan Ekonomi, HangZhou, ZheJiang
Jenis Perniagaan: Pengeluar/Kilang, Syarikat Perdagangan
Julat Perniagaan: Bahan Kimia, Elektrik & Elektronik, Jentera Pembuatan & Pemprosesan, Keselamatan & Perlindungan
Pensijilan Sistem Pengurusan: ISO 9001
Produk Utama: Pelletizer, Flaker, Pastillator, Granulator, Chemical Pelletizer, Vocs
Pengenalan Syarikat: HangZhou Raidsant Machinery Co., Ltd., sebelum ini dikenali sebagai Kilang Jentera Plastik HangZhou Xinte mengambil jurusan dalam menghasilkan jentera kitar semula plastik yang inovatif. Dengan pengalaman hampir 20 tahun, kami mempunyai pasaran yang baik di 20 wilayah di China, dan beberapa produk kami telah dieksport ke Indonesia, Rusia dan Vietnam, dsb. Produk utama kami termasuk DZ Type Pastillator, barisan kitar semula tayar sisa, Big Caliber Plastic Talian kitar semula mesin pencincang paip, mesin salutan timah penyepuhlindapan berterusan, PET jenis QX, Talian basuh PE & badan kapal, penghancur kitar semula plastik SDP dua rel, pemotongan panas SJ unit pembuatan butiran, barisan produk tiub PVC (cinquefoil), barisan produk bahan PVC berbentuk ganjil untuk pintu dan tingkap, barisan produk butiran dalam air dan Mesin pencincang untuk plastik dan kitar semula. Kami memperoleh 5 paten teknikal.
Syarikat kami memberi penekanan kepada pembinaan semula teknikal, mengimport teknologi canggih dari dalam dan luar negara, dan membangunkan produk baharu secara berterusan. Prinsip kami adalah mencabar untuk kualiti tinggi, menawarkan produk terbaik. Kami sedang berusaha untuk merealisasikan slogan kami. Memuaskan pelanggan kami adalah usaha kami yang kekal.
Kami sedang mencari pelanggan atau ejen luar negara. Jika anda berminat dengan cadangan kami, sila beritahu kami produk mana yang paling mungkin menarik minat anda atau pelanggan anda. Kami sepatutnya sangat berterima kasih jika anda memberi kami beberapa idea tentang prospek pasaran untuk produk kami. Kami berharap untuk mendengar maklumat yang menggalakkan daripada anda tidak lama lagi! Adalah menjadi matlamat kami bahawa kami berharap kami dapat membina hubungan yang baik dengan anda sekarang atau dalam masa terdekat. Sila jangan teragak-agak untuk menghubungi kami jika anda mempunyai sebarang pertanyaan atau permintaan.
Kami juga mengalu-alukan kedatangan anda ke syarikat kami untuk membincangkan perniagaan dan berunding dengan kami. Untuk meluaskan lagi pasaran dan pelanggan kami, syarikat kami mengalu-alukan pelanggan dari dalam dan luar negara dalam isyarat jenama baharu berdasarkan konsep pengurusan baharu sepenuhnya—kualiti, penghormatan, perkhidmatan. Kami sedang mencari sistem kualiti pengurusan ISO 90001 untuk memenuhi keperluan pelanggan kami!
Can a regenerative thermal oxidizer be retrofitted into an existing facility?
Yes, regenerative thermal oxidizers (RTOs) can be retrofitted into existing facilities under certain conditions. Retrofitting an RTO involves integrating the system into the existing infrastructure and process flow of the facility to control emissions from industrial processes. However, the feasibility of retrofitting an RTO depends on several factors related to the facility and the specific requirements of the application.
Here are some considerations for retrofitting an RTO into an existing facility:
- Space Availability: RTOs typically require a significant amount of physical space for installation. It’s important to assess whether the facility has adequate space to accommodate the size and layout requirements of the RTO system. This includes considering the space needed for the RTO unit itself, associated ductwork, auxiliary systems, and access for maintenance.
- Process Integration: Retrofitting an RTO involves integrating the system into the existing industrial process. This integration may require modifications to the process flow, such as rerouting ductwork, adding or modifying exhaust points, or coordinating with existing pollution control equipment. The compatibility of the RTO with the existing process and the ability to seamlessly integrate the system should be evaluated.
- Auxiliary Systems: In addition to the RTO unit, auxiliary systems may be required for effective operation and compliance. These systems can include pre-treatment equipment such as scrubbers or filters, heat recovery units, monitoring and control systems, and stack emissions monitoring equipment. The availability of space and compatibility with existing infrastructure should be considered for accommodating these auxiliary systems.
- Utility Requirements: RTOs have specific utility requirements, such as the need for natural gas or electricity for heating the combustion chamber and operating the control system. The availability and capacity of utilities at the existing facility should be assessed to ensure they can meet the demands of the RTO system.
- Structural Considerations: The structural integrity of the facility should be evaluated to determine if it can support the additional weight of the RTO and associated equipment. This assessment may involve consulting with structural engineers and considering any necessary reinforcements or modifications.
- Pematuhan Peraturan: Retrofitting an RTO may require obtaining permits and complying with environmental regulations. It is essential to assess the applicable regulations and ensure that the retrofit meets the necessary compliance requirements for emissions control.
It is important to consult with experienced engineering firms or RTO manufacturers who can assess the specific requirements and constraints of the facility. They can provide detailed evaluations, feasibility studies, and design recommendations for retrofitting an RTO into an existing facility. Their expertise can help ensure that the retrofit is successful, cost-effective, and compliant with environmental regulations.
Can regenerative thermal oxidizers handle corrosive exhaust gases?
Regenerative thermal oxidizers (RTOs) can be designed to handle corrosive exhaust gases effectively. However, the ability of an RTO to handle corrosive gases depends on several factors, including the choice of construction materials, operating conditions, and the specific corrosive nature of the exhaust gases. Here are some key points regarding the handling of corrosive exhaust gases in RTOs:
- Material Selection: The selection of appropriate construction materials is crucial when dealing with corrosive gases. RTOs can be constructed using materials that offer high resistance to corrosion, such as stainless steel, corrosion-resistant alloys (e.g., Hastelloy, Inconel), or coated materials. The choice of materials depends on the specific corrosive compounds present in the exhaust gases and their concentrations.
- Corrosion-Resistant Coatings: In addition to selecting corrosion-resistant materials, applying protective coatings can enhance the resistance of the RTO components to corrosive gases. Coatings such as ceramic coatings, epoxy coatings, or acid-resistant paints can provide an extra layer of protection against corrosion.
- Temperature Control: Maintaining appropriate operating temperatures in the RTO can help mitigate the corrosive effects of the exhaust gases. Higher temperatures can promote the decomposition of corrosive compounds, reducing their corrosive potential. Additionally, operating at higher temperatures can enhance the self-cleaning effect and prevent the accumulation of corrosive deposits on the surfaces.
- Gas Conditioning: Prior to entering the RTO, the exhaust gases can undergo gas conditioning processes to reduce their corrosive nature. This may involve pre-treatment methods such as scrubbing or neutralization to remove or neutralize corrosive compounds and reduce their concentration.
- Monitoring and Maintenance: Regular monitoring of the RTO performance and periodic maintenance are essential to ensure the effective handling of corrosive exhaust gases. Monitoring systems can track variables such as temperature, pressure, and gas composition to detect any deviations that may indicate corrosion-related issues. Proper maintenance, including cleaning and inspection of the components, helps identify and address any corrosion concerns in a timely manner.
It is important to note that the corrosiveness of exhaust gases can vary significantly depending on the specific industrial process and the pollutants involved. Therefore, when designing an RTO for handling corrosive gases, it is advisable to consult with experienced engineers or RTO manufacturers who can provide guidance on the appropriate design considerations and material selection.
By employing suitable materials, coatings, temperature control, gas conditioning, and maintenance practices, RTOs can effectively handle corrosive exhaust gases while ensuring their long-term performance and durability.
Apakah pengoksida terma regeneratif?
Pengoksida terma regeneratif (RTO) ialah peranti kawalan pencemaran udara termaju yang digunakan dalam aplikasi industri untuk membuang sebatian organik meruap (VOC), bahan cemar udara berbahaya (HAP) dan bahan cemar bawaan udara lain daripada gas ekzos. Ia beroperasi dengan menggunakan suhu tinggi untuk mengurai atau mengoksidakan bahan pencemar secara terma, menukarkannya kepada produk sampingan yang kurang berbahaya.
Bagaimanakah pengoksida terma regeneratif berfungsi?
RTO terdiri daripada beberapa komponen utama dan beroperasi melalui proses kitaran:
1. Plenum Masuk: Gas ekzos yang mengandungi bahan pencemar memasuki RTO melalui plenum masuk.
2. Katil Penukar Haba: RTO mengandungi berbilang katil penukar haba yang diisi dengan media penyimpanan haba, biasanya bahan seramik atau pembungkusan berstruktur. Katil penukar haba disusun secara berpasangan.
3. Injap Kawalan Aliran: Injap kawalan aliran mengarahkan aliran udara dan mengawal arah gas ekzos melalui RTO.
4. Kebuk Pembakaran: Gas ekzos, kini diarahkan ke dalam kebuk pembakaran, dipanaskan pada suhu tinggi, biasanya antara 1400°F (760°C) dan 1600°F (870°C). Julat suhu ini memastikan pengoksidaan haba yang berkesan bagi bahan pencemar.
5. Kemusnahan VOC: Suhu tinggi dalam kebuk pembakaran menyebabkan VOC dan bahan cemar lain bertindak balas dengan oksigen, mengakibatkan penguraian haba atau pengoksidaan. Proses ini memecahkan bahan pencemar kepada wap air, karbon dioksida, dan gas tidak berbahaya yang lain.
6. Pemulihan Haba: Gas-gas panas dan tulen yang meninggalkan kebuk pembakaran melalui plenum alir keluar dan mengalir melalui katil penukar haba yang berada dalam fasa operasi yang bertentangan. Media penyimpanan haba di dalam katil menyerap haba daripada gas yang keluar, yang memanaskan gas ekzos yang masuk.
7. Penukaran Kitaran: Selepas selang masa tertentu, injap kawalan aliran menukar arah aliran udara, membenarkan katil penukar haba yang memanaskan gas masuk kini menerima gas panas daripada kebuk pembakaran. Kitaran kemudian berulang, memastikan operasi berterusan dan cekap.
Kelebihan pengoksida terma regeneratif:
RTO menawarkan beberapa kelebihan dalam kawalan pencemaran udara industri:
1. Kecekapan Tinggi: RTO boleh mencapai kecekapan pemusnahan yang tinggi, biasanya melebihi 95%, dengan berkesan menyingkirkan pelbagai jenis bahan pencemar.
2. Pemulihan Tenaga: Mekanisme pemulihan haba dalam RTO membolehkan penjimatan tenaga yang ketara. Pemanasan awal gas yang masuk mengurangkan penggunaan bahan api yang diperlukan untuk pembakaran, menjadikan RTO cekap tenaga.
3. Keberkesanan kos: Walaupun pelaburan modal awal untuk RTO boleh menjadi ketara, penjimatan kos operasi jangka panjang melalui pemulihan tenaga dan kecekapan pemusnahan yang tinggi menjadikannya penyelesaian yang kos efektif sepanjang jangka hayat sistem.
4. Pematuhan Alam Sekitar: RTO direka bentuk untuk memenuhi peraturan pelepasan yang ketat dan membantu industri mematuhi piawaian dan permit kualiti udara.
5. serba boleh: RTO boleh mengendalikan pelbagai volum ekzos proses dan kepekatan pencemar, menjadikannya sesuai untuk pelbagai aplikasi perindustrian.
Secara keseluruhannya, pengoksida terma regeneratif adalah peranti kawalan pencemaran udara yang sangat cekap dan berkesan digunakan secara meluas dalam industri untuk meminimumkan pelepasan dan memastikan pematuhan alam sekitar.
editor by CX 2024-03-23