Yandex Metrika

Maklumat Asas.

Model NO.

RTO yang menakjubkan

taip

Insinerator

Kecekapan Tinggi

100

Penjimatan Tenaga

100

Penyelenggaraan Rendah

100

Operasi Mudah

100

Tanda dagangan

Bjamazing

Pakej Pengangkutan

Luar negara

Spesifikasi

111

asal usul

China

Kod HS

2221111

Penerangan Produk

RTO

Pengoksida Terma Penjanaan Semula

Berbanding dengan pembakaran pemangkin tradisional,; pengoksida haba langsung,; RTO mempunyai merit kecekapan pemanasan yang tinggi,; kos operasi yang rendah,; dan keupayaan untuk merawat gas buangan kepekatan rendah fluks besar.; Apabila kepekatan VOC tinggi,; kitar semula haba sekunder boleh direalisasikan,; yang akan mengurangkan kos operasi.; Kerana RTO boleh memanaskan gas sisa mengikut tahap melalui penumpuk haba seramik,; yang boleh membuat gas buangan dipanaskan sepenuhnya dan retak tanpa sudut mati (kecekapan rawatan> 99%);,; yang mengurangkan NOX dalam gas yang meletihkan,; jika ketumpatan VOC >1500mg/Nm3,; apabila gas buangan mencapai kawasan retak,; ia telah dipanaskan sehingga suhu retak oleh penumpuk haba,; penunu akan ditutup di bawah keadaan ini.;

RTO boleh dibahagikan kepada jenis ruang dan jenis berputar mengikut mod operasi perbezaan.; RTO jenis Rotary mempunyai kelebihan dalam tekanan sistem,; kestabilan suhu,; jumlah pelaburan,; dll

jenis RTO  KecekapanPerubahan tekanan
(mmAq);
Saiz(maks); volum rawatan  
 
Kecekapan rawatan Kecekapan kitar semula haba  
RTO jenis putar99%97%0-4kecil
(1 kali);
50000Nm3/j  
RTO jenis tiga ruang99%97%  0-10besar
(1.;5kali);
100000Nm3/j
RTO jenis dua ruang95%95%0-20tengah
(1.;2kali);
100000Nm3/j  

Pengoksida Terma Penjanaan Semula,; Pengoksida Terma Penjanaan Semula,; Pengoksida Terma Penjanaan Semula,; Pengoksida Terma,; Pengoksida Terma,; Pengoksida Terma,; pengoksida,; pengoksida,; pengoksida,; insinerator,; insinerator,; insinerator,; rawatan gas buangan,; rawatan gas buangan,; rawatan gas buangan,; rawatan VOC,; rawatan VOC,; rawatan VOC,; RTO,; RTO,; RTO,; Rotary RTO,; Rotary RTO,; Rotary RTO,; RTO Dewan,; RTO Dewan,; RTO Dewan

Alamat: tingkat 8, E1, bangunan Pinwei, jalan Dishengxi, Yizhuang, ZheJiang, China

Jenis Perniagaan: Pengeluar/Kilang, Syarikat Perdagangan

Julat Perniagaan: Elektrik & Elektronik, Peralatan & Komponen Industri, Jentera Pembuatan & Pemprosesan, Metalurgi, Mineral & Tenaga

Pensijilan Sistem Pengurusan: ISO 9001, ISO 14001

Produk Utama: Rto, Talian Salutan Warna, Talian Galvanisasi, Pisau Udara, Alat Ganti untuk Talian Pemprosesan, Coater, Peralatan Bebas, Gulung Sink, Projek Ubahsuai, Blower

Pengenalan Syarikat: ZheJiang Amazing Science & Technology Co., Ltd ialah sebuah syarikat berteknologi tinggi yang berkembang maju, terletak di ZheJiang Economic and Technological Development Area(BDA). Berpegang kepada konsep Realistik, Inovatif, Fokus dan Cekap, syarikat kami menyediakan perkhidmatan terutamanya dalam industri rawatan gas sisa (VOC) dan peralatan metalurgi China dan juga seluruh dunia. Kami mempunyai teknologi canggih dan pengalaman yang kaya dalam projek rawatan gas buangan VOC, yang rujukannya telah berjaya digunakan untuk industri salutan, getah, elektronik, percetakan, dll. Kami juga mempunyai pengumpulan teknologi selama bertahun-tahun dalam penyelidikan dan pembuatan flat talian pemprosesan keluli, dan mempunyai hampir 100 contoh aplikasi.

Syarikat kami menumpukan pada penyelidikan, reka bentuk, pengilangan, pemasangan dan pentauliahan sistem rawatan gas sisa organik VOC dan projek merombak dan mengemas kini untuk penjimatan tenaga dan perlindungan alam sekitar barisan pemprosesan keluli rata. Kami boleh menyediakan pelanggan penyelesaian lengkap untuk perlindungan alam sekitar, penjimatan tenaga, peningkatan kualiti produk dan aspek lain.

Kami juga terlibat dalam pelbagai alat ganti dan peralatan bebas untuk garis salutan warna, garis galvanizing, garis penjerukan, seperti penggelek, pengganding, penukar haba, recuperator, pisau udara, peniup, pengimpal, penyamara ketegangan, pas kulit, sambungan pengembangan, ricih, penyambung , penjahit, penunu, tiub berseri, motor gear, pengurang, dsb.

pengoksida terma regeneratif

What is the cost of installing a regenerative thermal oxidizer?

The cost of installing a regenerative thermal oxidizer (RTO) can vary significantly depending on several factors. These factors include the size and capacity of the RTO, the specific requirements of the application, site conditions, and any additional customization or engineering needed. However, it’s important to note that RTOs are generally considered a significant capital investment due to their complex design and high-performance capabilities.

Here are some cost considerations associated with installing an RTO:

  • RTO Size and Capacity: The size and capacity of the RTO, typically measured in terms of exhaust flow rate and pollutant concentration, are important cost factors. Larger RTOs capable of handling higher exhaust volumes and pollutant concentrations generally have higher upfront costs compared to smaller units.
  • Engineering and Customization: The engineering and customization requirements for integrating the RTO into the existing industrial process can impact the installation cost. This includes factors such as ductwork modifications, electrical connections, and any necessary process integration to ensure proper functioning of the RTO within the overall system.
  • Site Preparation: The site where the RTO will be installed may require preparation to accommodate the equipment. This can involve constructing foundations, providing adequate space for the RTO and associated components, and ensuring proper access for installation and maintenance.
  • Auxiliary Systems and Equipment: In addition to the RTO itself, there may be auxiliary systems and equipment required for effective operation. This can include pre-treatment systems, such as scrubbers or filters, heat recovery units, monitoring and control systems, and stack emissions monitoring equipment. The cost of these additional components should be considered in the overall installation cost.
  • Installation Labor and Equipment: The cost of labor and equipment required for the installation process, including crane services and specialized contractors, should be factored into the overall cost. The complexity of the installation and any specific site challenges can influence these costs.
  • Permits and Compliance: Obtaining necessary permits and complying with regulatory requirements can involve additional costs. This includes fees for environmental permits, engineering studies, emissions testing, and compliance documentation.

Due to the many variables involved, it is challenging to provide a specific cost range for installing an RTO. It is recommended to consult with reputable RTO manufacturers or engineering firms, who can assess the specific requirements of the application and provide detailed cost estimates based on the project scope.

pengoksida terma regeneratif

Can regenerative thermal oxidizers handle corrosive exhaust gases?

Regenerative thermal oxidizers (RTOs) can be designed to handle corrosive exhaust gases effectively. However, the ability of an RTO to handle corrosive gases depends on several factors, including the choice of construction materials, operating conditions, and the specific corrosive nature of the exhaust gases. Here are some key points regarding the handling of corrosive exhaust gases in RTOs:

  • Material Selection: The selection of appropriate construction materials is crucial when dealing with corrosive gases. RTOs can be constructed using materials that offer high resistance to corrosion, such as stainless steel, corrosion-resistant alloys (e.g., Hastelloy, Inconel), or coated materials. The choice of materials depends on the specific corrosive compounds present in the exhaust gases and their concentrations.
  • Corrosion-Resistant Coatings: In addition to selecting corrosion-resistant materials, applying protective coatings can enhance the resistance of the RTO components to corrosive gases. Coatings such as ceramic coatings, epoxy coatings, or acid-resistant paints can provide an extra layer of protection against corrosion.
  • Temperature Control: Maintaining appropriate operating temperatures in the RTO can help mitigate the corrosive effects of the exhaust gases. Higher temperatures can promote the decomposition of corrosive compounds, reducing their corrosive potential. Additionally, operating at higher temperatures can enhance the self-cleaning effect and prevent the accumulation of corrosive deposits on the surfaces.
  • Gas Conditioning: Prior to entering the RTO, the exhaust gases can undergo gas conditioning processes to reduce their corrosive nature. This may involve pre-treatment methods such as scrubbing or neutralization to remove or neutralize corrosive compounds and reduce their concentration.
  • Monitoring and Maintenance: Regular monitoring of the RTO performance and periodic maintenance are essential to ensure the effective handling of corrosive exhaust gases. Monitoring systems can track variables such as temperature, pressure, and gas composition to detect any deviations that may indicate corrosion-related issues. Proper maintenance, including cleaning and inspection of the components, helps identify and address any corrosion concerns in a timely manner.

It is important to note that the corrosiveness of exhaust gases can vary significantly depending on the specific industrial process and the pollutants involved. Therefore, when designing an RTO for handling corrosive gases, it is advisable to consult with experienced engineers or RTO manufacturers who can provide guidance on the appropriate design considerations and material selection.

By employing suitable materials, coatings, temperature control, gas conditioning, and maintenance practices, RTOs can effectively handle corrosive exhaust gases while ensuring their long-term performance and durability.

pengoksida terma regeneratif

Apakah keperluan penyelenggaraan untuk pengoksida terma regeneratif?

Mengekalkan pengoksida terma penjanaan semula (RTO) adalah penting untuk memastikan prestasi optimum, jangka hayat dan pematuhan kepada peraturan alam sekitar. Berikut ialah beberapa keperluan penyelenggaraan utama untuk RTO:

  • Pemeriksaan berkala: Lakukan pemeriksaan rutin untuk mengenal pasti sebarang tanda haus, kakisan atau kerosakan pada komponen RTO. Ini termasuk memeriksa injap, peredam, kipas, kebuk pembakaran, penukar haba dan katil media seramik. Pemeriksaan membantu mengesan masalah yang berpotensi lebih awal dan membolehkan pembaikan atau penggantian tepat pada masanya.
  • Pembersihan dan Penggantian Komponen: Bersihkan atau gantikan komponen mengikut keperluan untuk mengekalkan kefungsian yang betul. Ini mungkin termasuk membersihkan permukaan penukar haba yang tersumbat atau kotor, menggantikan injap dan peredam yang rosak atau haus, dan menggantikan katil media seramik secara berkala jika ia rosak atau tercemar.
  • Memantau Parameter Operasi: Sentiasa memantau dan merekod parameter operasi seperti suhu, aliran udara, pembezaan tekanan dan kepekatan gas. Penyimpangan daripada julat operasi biasa boleh menunjukkan potensi masalah atau ketidakcekapan yang memerlukan perhatian.
  • Penentukuran Instrumen: Kalibrasi instrumen dan penderia yang digunakan untuk tujuan pemantauan dan kawalan untuk memastikan pengukuran parameter yang tepat seperti suhu, tekanan dan kadar aliran. Penentukuran yang betul membantu mengekalkan operasi RTO yang boleh dipercayai dan tepat.
  • Pembersihan Sistem Pemulihan Haba: Bersihkan sistem pemulihan haba, termasuk permukaan penukar haba, untuk mengeluarkan sebarang zarah terkumpul atau kekotoran. Ini memastikan pemindahan haba yang cekap dan menghalang pengumpulan mendapan yang boleh mengurangkan prestasi RTO.
  • Pematuhan dengan Piawaian Keselamatan: Patuhi piawaian dan garis panduan keselamatan untuk bekerja dengan RTO. Ini termasuk prosedur lockout/tagout yang betul semasa aktiviti penyelenggaraan, memakai peralatan pelindung diri yang sesuai, dan mematuhi protokol keselamatan untuk meminimumkan risiko kepada kakitangan dan peralatan.
  • Dokumentasi dan Penyimpanan Rekod: Mengekalkan rekod menyeluruh aktiviti penyelenggaraan, pemeriksaan, pembaikan dan sebarang pengubahsuaian yang dibuat kepada RTO. Dokumentasi membantu menjejaki sejarah peralatan, membantu dalam penyelesaian masalah dan menyediakan rekod pematuhan dengan keperluan kawal selia.

Adalah penting untuk ambil perhatian bahawa keperluan penyelenggaraan khusus mungkin berbeza-beza bergantung pada pengesyoran pengilang RTO, reka bentuk sistem, keadaan operasi dan keperluan kawal selia yang berkenaan. Mengikuti garis panduan pengilang, menjalankan pemeriksaan biasa dan melaksanakan program penyelenggaraan proaktif yang disesuaikan dengan RTO khusus adalah penting untuk memastikan operasi yang boleh dipercayai dan jangka hayatnya.

China Best Sales Rto/Regenerative Thermal Oxidizer
editor by CX 2024-04-13

ms_MYMS