How to Troubleshoot RTO with Heat Recovery Problems?
Regenerative Thermal Oxidizers (RTOs) are used in industrial applications to control emissions of volatile organic compounds (VOCs) and hazardous air pollutants (HAPs). When integrated with a heat recovery system, RTOs can help to reduce overall operating costs by capturing waste heat and reusing it to preheat incoming process air. However, like any system, RTOs can encounter issues that affect their performance. In this article, we will explore how to troubleshoot RTO with heat recovery problems and keep your system running efficiently.
Check the Heat Recovery System
- Inspect the heat exchangers and ensure that they are free of fouling or blockages. Fouling can occur due to the buildup of dirt, dust, or other contaminants on the heat exchanger surface, reducing its efficiency.
- Check the incoming and outgoing temperatures of the heat recovery system. A significant difference in these temperatures could indicate that the heat exchangers are not functioning efficiently.
- Inspect the ductwork for leaks or damage. Leaks can result in the loss of heat, reducing the effectiveness of the heat recovery system.
- Verify that the heat recovery system is properly sized for the RTO and the process it serves. An undersized system will not be able to capture enough heat, while an oversized system may increase capital costs without providing any additional benefit.
Check the RTO Valves
- Inspect the valves that control the flow of process air and exhaust gas through the RTO. Ensure that they are functioning correctly and not leaking or stuck in a partially open position.
- Verify that the valves are properly sized for the RTO and the process it serves. An undersized valve may limit airflow, while an oversized valve may reduce the effectiveness of the RTO.
- Check the valve actuation system to ensure that it is functioning correctly and not causing any delays or malfunctions.
- Inspect the valve seals and gaskets. Leaks can result in the loss of heat and reduce the efficiency of the RTO.
Check the Combustion System
- Inspect the burner system and ensure that it is clean and free of debris. Buildup inside the burner can reduce its efficiency and effectiveness.
- Verify that the fuel and air supplies to the burner are correctly adjusted. A poorly adjusted burner can result in incomplete combustion and increase the emissions of VOCs and HAPs.
- Check the flame sensor and ensure that it is functioning correctly. A faulty flame sensor can result in the shutdown of the combustion system.
- Monitor the temperatures within the RTO and ensure that they are within the operating range. High temperatures can damage the RTO, while low temperatures may result in incomplete combustion.
Check the Control System
- Inspect the control panel and ensure that all the sensors, switches, and gauges are functioning correctly.
- Verify that the control system is correctly programmed and calibrated. A poorly calibrated system can result in fluctuations in temperature or airflow, reducing the efficiency of the RTO.
- Monitor the performance of the RTO and track any changes or trends in its operation. Analyzing this data can help to identify potential issues before they become significant problems.
- Ensure that the control system has adequate backup and redundancy systems in place to prevent downtime or loss of data.
Check the Maintenance Schedule
- Verify that the RTO is being maintained according to its recommended schedule. Neglected maintenance can result in decreased efficiency and increased emissions.
- Ensure that all maintenance procedures are being performed correctly and by qualified personnel.
- Track the maintenance history of the RTO and analyze any trends or patterns that emerge. This data can help to identify recurring issues and develop strategies to prevent them.
- Ensure that all maintenance records are properly documented and retained for future reference.
結論
Regenerative Thermal Oxidizers with heat recovery systems are an effective way to control emissions and reduce operating costs. However, they require regular maintenance and monitoring to ensure that they are operating efficiently and effectively. By following the troubleshooting steps outlined in this article, you can identify potential issues and keep your RTO running smoothly.
当社は、揮発性有機化合物(VOC)廃ガス処理とハイエンド機器製造の炭素削減および省エネ技術を専門とするハイテク企業です。当社のコア技術チームは、研究者レベルのシニアエンジニア3名と航空宇宙液体ロケットエンジン研究所(航空宇宙第六研究所)のシニアエンジニア16名を含む60名以上の研究開発技術者で構成されています。当社は、熱エネルギー、燃焼、密封、自動制御の4つのコアテクノロジーを持っています。温度場と気流場のシミュレーションモデリングと計算が可能です。また、セラミック蓄熱材料の性能テスト、分子ふるい吸着材料の選択、VOC有機物の高温焼却および酸化特性の実験テストを行う能力もあります。当社は、古都西安にRTO技術研究開発センターと排気ガス炭素削減エンジニアリング技術センターを建設し、3万m2 楊陵に生産拠点を構え、RTO機器の生産・販売量は世界トップクラスです。
当社のR&Dプラットフォーム
- 高効率燃焼制御技術試験ベンチ – このテストベンチは、さまざまな材料や燃料の燃焼効率をテストするために使用され、得られたデータを使用して RTO 機器を最適化し、効率を高めて炭素排出量を削減できます。
- 分子ふるい吸着効率試験ベンチ – このテストベンチは、分子ふるいの吸着容量と効率を評価するために使用され、RTO 装置に最も効率的な吸着材料を選択できるようにします。
- 高効率セラミック蓄熱技術試験ベンチ – このテストベンチは、さまざまなセラミック材料の蓄熱容量をテストし、RTO 装置の省エネ性能を最適化するために使用されます。
- 超高温廃熱回収試験ベンチ – このテストベンチは、VOC有機物の高温焼却および酸化特性をテストし、RTO装置の省エネ性能を最適化するために使用されます。
- 気体流体シール技術テストベンチ – このテストベンチは、さまざまな圧力、温度、化学環境下でのさまざまなシーリング材のシーリング性能をテストするために使用され、RTO 装置に最適なシーリング材を選択できるようにします。

当社の特許と栄誉
コア技術面では、主要部品を特許技術でカバーする21件の発明特許を含む68件の特許を申請しており、発明特許4件、実用新案特許41件、外観特許6件、ソフトウェア著作権7件を取得しています。

当社の生産能力
- 鋼板および鋼形材の自動ショットブラスト生産ライン – この生産ラインは、鋼板や鋼材の表面から錆や不純物を効率的に除去し、RTO 機器の生産品質を保証します。
- 手動ショットブラスト生産ライン – この生産ラインは、不規則なワークピースや部品の表面を効果的に洗浄できます。
- 除塵環境保護装置 – この装置は、生産工場の環境からほこりやその他の汚染物質を効果的に除去できます。
- 自動スプレー塗装室 – この部屋ではワークピースにスプレー塗装することができ、人件費を節約し、塗装品質を向上させることができます。
- 乾燥室 – この部屋では、塗装されたワークピースや部品を迅速かつ均一に乾燥させることができ、生産効率が向上します。

当社は、お客様の環境目標の達成を支援する情熱と専門知識を持っています。当社と協力することで、お客様は次のことが期待できます。
- 高度な研究開発の専門知識と最先端の技術
- 顧客のニーズに合わせた総合的な環境ソリューション
- 高品質で信頼性の高い機器製造および設置サービス
- 効率的なプロジェクト管理とエンジニアリングサポート
- 競争力のある価格設定と長期的な投資価値
- 優れたアフターサービスと技術サポート

著者宮