{"id":4229,"date":"2024-12-18T08:55:27","date_gmt":"2024-12-18T08:55:27","guid":{"rendered":"https:\/\/regenerative-thermal-oxidizers.com\/?page_id=4229"},"modified":"2024-12-23T08:56:43","modified_gmt":"2024-12-23T08:56:43","slug":"reusing-low-concentration-methane-gas","status":"publish","type":"page","link":"https:\/\/regenerative-thermal-oxidizers.com\/uk\/reusing-low-concentration-methane-gas\/","title":{"rendered":"Reusing Low-Concentration Methane Gas"},"content":{"rendered":"

[et_pb_section fb_built=”1″ fullwidth=”on” _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}”][et_pb_fullwidth_header title=”Reusing Low-Concentration Methane & Vam” button_one_text=”Click Here” _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}”]<\/p>\n

Discover how our advanced RTO systems enable efficient reuse of low-concentration gases, reducing emissions and lowering costs. Optimize your processes with sustainable, high-performance solutions today.<\/span><\/p>\n

[\/et_pb_fullwidth_header][\/et_pb_section][et_pb_section fb_built=”1″ _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}”][et_pb_row _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}”][et_pb_column type=”4_4″ _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}”][et_pb_text _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}”]<\/p>\n

Current Situation of Low Concentration Methane Utilization<\/strong><\/h2>\n

[\/et_pb_text][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=\u201d4.27.4\u2033 _module_preset=\u201d\u0437\u0430 \u0437\u0430\u043c\u043e\u0432\u0447\u0443\u0432\u0430\u043d\u043d\u044f\u043c\u201d global_colors_info=\u201d{}\u201d][et_pb_column type=\u201d4_4\u2033 _builder_version=\u201d4.27.4\u2033 _module_preset=\u201d\u0437\u0430 \u0437\u0430\u043c\u043e\u0432\u0447\u0443\u0432\u0430\u043d\u043d\u044f\u043c\u201d global_colors_info=\u201d{}\u201d][et_pb_text _builder_version=\u201d4.27.4\u2033 _module_preset=\u201d\u0437\u0430 \u0437\u0430\u043c\u043e\u0432\u0447\u0443\u0432\u0430\u043d\u043d\u044f\u043c\u201d global_colors_info=\u201d{}\u201d]<\/p>\n

Low concentration methane has a large emission volume<\/h3>\n
    \n
  • In 2018, the global coal mine methane leakage was 40 million tons, equivalent to the emission of 1 billion tons of CO2 equivalent greenhouse gases. China’s emissions account for over half of the total global methane emissions from coal mining.<\/li>\n
  • In 2018, China extracted 13 billion cubic meters of gas, of which 5.3 billion cubic meters with a concentration greater than 9% were utilized, with a utilization rate of 40.7%.<\/li>\n
  • During the coal mining process, about 60% -70% of the low concentration gas is below 9%, with a utilization rate of only 2%. Most of it is not utilized and directly discharged and leaked into the atmosphere, polluting the environment.<\/li>\n
  • China’s coal mines emit a total of 24 billion cubic meters of methane into the atmosphere every year, accounting for one-third of the total industrial methane exhaust volume and generating 200 million tons of carbon emissions.<\/li>\n
  • Gas is flammable and explosive (5%~15%) (safety issue).<\/li>\n<\/ul>\n

    [\/et_pb_text][\/et_pb_column][\/et_pb_row][et_pb_row column_structure=”2_5,3_5″ _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}”][et_pb_column type=”2_5″ _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}”][et_pb_image src=”https:\/\/regenerative-thermal-oxidizers.com\/wp-content\/uploads\/2024\/12\/0-methane-gas-1-2.webp” alt=”methane gas ” title_text=”0-methane gas 1 (2)” _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}”][\/et_pb_image][\/et_pb_column][et_pb_column type=”3_5″ _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}”][et_pb_text _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}”]<\/p>\n

    Methane gas properties: fuel+non CO2 greenhouse gases<\/h3>\n
      \n
    • Methane Gas is a clean fuel resource.<\/strong><\/em><\/li>\n
    • Gas (methane) is a greenhouse gas. The greenhouse effect of methane has a “100 year time frame warming potential GWP” that is 28 times that of carbon dioxide.<\/li>\n
    • Deep reduction of methane emissions will be a necessary condition for achieving global warming control below 1.5 \u2103<\/em><\/strong>.<\/li>\n
    • In January 2021, the Ministry of Ecology and Environmental Protection pointed out the need to strengthen greenhouse gas monitoring and gradually incorporate it into the overall implementation of the ecological environment monitoring system. At the level of key emission point sources, pilot projects will be carried out to monitor methane emissions in key industries such as oil and gas, coal mining, etc.<\/li>\n
    • The restart of the National Certified Voluntary Emission Reduction (CCER) program is imminent. (Calculated at 50 yuan\/ton, equivalent to a gas value of approximately 0.75 yuan\/Nm3).<\/li>\n
    • The oxidation and destruction of exhaust gas will become one of the directions for methane emission reduction in the future.<\/li>\n<\/ul>\n

      [\/et_pb_text][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=\u201d4.27.4\u2033 _module_preset=\u201d\u0437\u0430 \u0437\u0430\u043c\u043e\u0432\u0447\u0443\u0432\u0430\u043d\u043d\u044f\u043c\u201d global_colors_info=\u201d{}\u201d][et_pb_column type=\u201d4_4\u2033 _builder_version=\u201d4.27.4\u2033 _module_preset=\u201d\u0437\u0430 \u0437\u0430\u043c\u043e\u0432\u0447\u0443\u0432\u0430\u043d\u043d\u044f\u043c\u201d global_colors_info=\u201d{}\u201d][et_pb_text _builder_version=\u201d4.27.4\u2033 _module_preset=\u201d\u0437\u0430 \u0437\u0430\u043c\u043e\u0432\u0447\u0443\u0432\u0430\u043d\u043d\u044f\u043c\u201d global_colors_info=\u201d{}\u201d]<\/p>\n

      Reuse mode of low concentration methane<\/strong><\/h2>\n

      [\/et_pb_text][\/et_pb_column][\/et_pb_row][et_pb_row column_structure=”1_4,1_4,1_4,1_4″ use_custom_gutter=”on” gutter_width=”1″ _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}”][et_pb_column type=”1_4″ _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}”][et_pb_icon font_icon=”||fa||900″ _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}”][\/et_pb_icon][et_pb_text _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}” content__hover_enabled=”on|hover” content__hover=”<\/p>\n

        \n
      • Vacuum pressure swing adsorption technology (adsorption of methane adsorbent, adsorption of non methane adsorbent method)<\/span><\/li>\n
      • Raise the concentration to over 30% and enter the coalbed methane civil pipeline network. (A small amount)<\/span><\/li>\n
      • Low concentration gas dehydration and adsorbent performance affect purification.<\/span><\/li>\n
      • The gas concentration and volume are unstable.<\/span><\/li>\n<\/ul>\n

        ” background__hover_enabled=”on|hover” background_color__hover=”#0C71C3″ background_enable_color__hover=”on”]<\/p>\n

        <\/h4>\n

        Purification and supply mode<\/h4>\n
          <\/ul>\n

          [\/et_pb_text][\/et_pb_column][et_pb_column type=”1_4″ _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}”][et_pb_icon font_icon=”||fa||900″ _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}”][\/et_pb_icon][et_pb_text _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}” content__hover_enabled=”on|hover” content__hover=”<\/p>\n

            \n
          • Methane internal combustion engine exhaust heat recovery for supplying saturated steam or hot water.<\/span><\/li>\n
          • Methane thermal storage oxidation heating can provide high-temperature flue gas or steam. (Anti freezing of wellbore)<\/span><\/li>\n
          • Heating is limited to northern coal mines, and a small number of southern coal mines require cooling to meet mine cooling needs.<\/span><\/li>\n
          • The short heating time is not conducive to maximizing the utilization of methane throughout the year.<\/span><\/li>\n<\/ul>\n

            ” background__hover_enabled=”on|hover” background_color__hover=”#0C71C3″ background_enable_color__hover=”on”]<\/p>\n

            <\/h4>\n

            Heating (cooling) mode<\/h4>\n
              <\/ul>\n

              [\/et_pb_text][\/et_pb_column][et_pb_column type=”1_4″ _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}”][et_pb_icon font_icon=”||fa||900″ _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}”][\/et_pb_icon][et_pb_text _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}” content__hover_enabled=”on|hover” content__hover=”<\/p>\n

                \n
              • Low concentration gas internal combustion engine power generation.<\/span><\/li>\n
              • Low concentration gas with a concentration of 9% to 30% is used for internal combustion engine power generation.<\/span>
                NOx emissions issue.<\/span><\/li>\n
              • Thermal storage oxidation waste heat power generation. The gas concentration is 1.2%, and the initial investment is relatively large<\/span><\/li>\n
              • The electricity price directly determines the economic benefits of the project, whether it is for self use by the coal mine or for grid connection. <\/span><\/li>\n<\/ul>\n

                ” background__hover_enabled=”on|hover” background_color__hover=”#0C71C3″ background_enable_color__hover=”on”]<\/p>\n

                <\/h4>\n

                Power generation mode<\/h4>\n
                  <\/ul>\n

                  [\/et_pb_text][\/et_pb_column][et_pb_column type=”1_4″ _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}”][et_pb_icon font_icon=”||fa||400″ _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}”][\/et_pb_icon][et_pb_text _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}” content__hover_enabled=”on|hover” content__hover=”<\/p>\n

                    \n
                  • Gas oxidation heat is generated by a waste heat boiler to produce steam with medium temperature, medium pressure or above parameters, equipped with a steam turbine to provide electricity and steam. (Development direction)<\/span><\/li>\n<\/ul>\n

                    ” background__hover_enabled=”on|hover” background_color__hover=”#0C71C3″ background_enable_color__hover=”on”]<\/p>\n

                    <\/h4>\n

                    Thermal storage oxidation cogeneration mode<\/h4>\n
                      <\/ul>\n

                      [\/et_pb_text][\/et_pb_column][\/et_pb_row][\/et_pb_section][et_pb_section fb_built=\u201d1\u2033 _builder_version=\u201d4.27.4\u2033 _module_preset=\u201d\u0437\u0430 \u0437\u0430\u043c\u043e\u0432\u0447\u0443\u0432\u0430\u043d\u043d\u044f\u043c\u201d global_colors_info=\u201d{}\u201d][et_pb_row _builder_version=\u201d4.27.4\u2033 _module_preset=\u201d\u0437\u0430 \u0437\u0430\u043c\u043e\u0432\u0447\u0443\u0432\u0430\u043d\u043d\u044f\u043c\u201d global_colors_info=\u201d{}\u201d][et_pb_column type=\u201d4_4\u2033 _builder_version=\u201d4.27.4\u2033 _module_preset=\u201d\u0437\u0430 \u0437\u0430\u043c\u043e\u0432\u0447\u0443\u0432\u0430\u043d\u043d\u044f\u043c\u201d global_colors_info=\u201d{}\u201d][et_pb_text _builder_version=\u201d4.27.4\u2033 _module_preset=\u201d\u0437\u0430 \u0437\u0430\u043c\u043e\u0432\u0447\u0443\u0432\u0430\u043d\u043d\u044f\u043c\u201d global_colors_info=\u201d{}\u201d]<\/p>\n

                      Cascade and Management of Methane Concentration in Coal Mines
                      <\/strong>(Taking China as an Example in 2020)<\/h2>\n

                      [\/et_pb_text][\/et_pb_column][\/et_pb_row][et_pb_row column_structure=”1_4,3_4″ use_custom_gutter=”on” gutter_width=”1″ _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}”][et_pb_column type=”1_4″ _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}”][et_pb_text _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}”]<\/p>\n

                      The coalbed methane associated with coal mining is commonly known as “gas”, and its main component is methane (CH4).
                      At present, all gas with a concentration below 8% is released into the atmosphere, causing a large amount of pollution.
                      Fully utilizing these resources for heating and power generation can achieve significant economic and carbon reduction benefits<\/p>\n

                      [\/et_pb_text][\/et_pb_column][et_pb_column type=”3_4″ _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}”][et_pb_image src=”https:\/\/regenerative-thermal-oxidizers.com\/wp-content\/uploads\/2024\/12\/0-methane-gas-2.webp” alt=”methane gas ” title_text=”0-methane gas 2″ _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}”][\/et_pb_image][\/et_pb_column][\/et_pb_row][\/et_pb_section][et_pb_section fb_built=”1″ _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}”][et_pb_row _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}”][et_pb_column type=”4_4″ _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}”][et_pb_text _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}”]<\/p>\n

                      Thermal Storage and Oxidation Energy Cascade Utilization Technology<\/strong><\/h2>\n

                      [\/et_pb_text][et_pb_image src=”https:\/\/regenerative-thermal-oxidizers.com\/wp-content\/uploads\/2024\/12\/0-methane-gas-3.webp” alt=”methane gas” title_text=”0-methane gas 3″ _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}”][\/et_pb_image][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}”][et_pb_column type=”4_4″ _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}”][et_pb_text _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}”]<\/p>\n

                      Process flow diagram<\/strong><\/h2>\n

                      [\/et_pb_text][et_pb_image src=”https:\/\/regenerative-thermal-oxidizers.com\/wp-content\/uploads\/2024\/12\/0-methane-gas-4-2.webp” alt=”methane gas” title_text=”0-methane gas 4 (2)” _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}”][\/et_pb_image][\/et_pb_column][\/et_pb_row][\/et_pb_section][et_pb_section fb_built=”1″ _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}”][et_pb_row _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}”][et_pb_column type=”4_4″ _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}”][et_pb_text _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}”]<\/p>\n

                      Safe transportation and blending of low concentration CH4 and Vam<\/strong><\/h2>\n

                      [\/et_pb_text][et_pb_text _builder_version=\u201d4.27.4\u2033 _module_preset=\u201d\u0437\u0430 \u0437\u0430\u043c\u043e\u0432\u0447\u0443\u0432\u0430\u043d\u043d\u044f\u043c\u201d global_colors_info=\u201d{}\u201d]<\/p>\n

                        \n
                      • Function:<\/strong>
                        Safely transport low concentration gas from the exhaust end to the gas consumption end, and ensure the quality of the transported gas; The exhaust end involved is a gas extraction station, and the gas end involved is a blending system.
                        <\/strong><\/li>\n
                      • \u0412\u0441\u0442\u0430\u043d\u043e\u0432\u043b\u0435\u043d\u043d\u044f:<\/strong>
                        The three-way pipe directly connected to the exhaust outlet of the gas extraction station does not require pipeline modification.<\/li>\n<\/ul>\n

                        [\/et_pb_text][et_pb_text _builder_version=”4.27.4″ _module_preset=”default” header_3_text_color=”#0C71C3″ hover_enabled=”0″ global_colors_info=”{}” sticky_enabled=”0″]<\/p>\n

                        \u00a0Main Equipment \u2460 — Electric release valve<\/span><\/strong><\/h3>\n
                          \n
                        • Principle and Function:<\/strong>
                          The electric release device is mainly used to achieve emergency release of system pressure, installed at the beginning and end of the conveying pipeline, and focuses more on the protection of coal mine gas drainage stations and blending systems.<\/li>\n
                        • Installation requirements:<\/strong>
                          Installed on the end discharge pipe of the conveying pipeline and the outlet exhaust pipeline of the coal mine gas drainage station. A dry flame arrester should be installed at the rear end of the release valve to ensure that the released gas does not affect the pipeline;<\/li>\n<\/ul>\n

                          [\/et_pb_text][et_pb_text _builder_version=”4.27.4″ _module_preset=”default” header_3_text_color=”#0C71C3″ hover_enabled=”0″ global_colors_info=”{}” sticky_enabled=”0″]<\/p>\n

                          \u00a0Main Equipment \u2461 — Powder automatic powder spraying and explosion suppression device<\/span><\/strong><\/h3>\n
                            \n
                          • Principle and Function:<\/strong>
                            The electric release device is mainly used to achieve emergency release of system pressure, installed at the beginning and end of the conveying pipeline, and focuses more on the protection of coal mine gas drainage stations and blending systems.<\/li>\n
                          • Installation requirements:<\/strong>
                            Installed on the end discharge pipe of the conveying pipeline and the outlet exhaust pipeline of the coal mine gas drainage station. A dry flame arrester should be installed at the rear end of the release valve to ensure that the released gas does not affect the pipeline;<\/li>\n<\/ul>\n

                            [\/et_pb_text][\/et_pb_column][\/et_pb_row][et_pb_row column_structure=”1_2,1_2″ _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}”][et_pb_column type=”1_2″ _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}”][et_pb_image src=”https:\/\/regenerative-thermal-oxidizers.com\/wp-content\/uploads\/2024\/12\/0-methane-gas-5.webp” alt=”Powder automatic powder spraying and explosion suppression device” title_text=”0-methane gas 5″ _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}”][\/et_pb_image][et_pb_text _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}”]<\/p>\n

                            1. Explosion suppression device nozzle<\/p>\n

                            2. explosion suppression device powder storage cylinder<\/p>\n

                            3. fire extinguishing agent buffer<\/p>\n

                            4. gas generator<\/p>\n

                            5. terminal<\/p>\n

                            6. cable<\/p>\n

                            7. controller<\/p>\n

                            8. ultraviolet flame sensor<\/p>\n

                            [\/et_pb_text][\/et_pb_column][et_pb_column type=”1_2″ _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}”][et_pb_image src=”https:\/\/regenerative-thermal-oxidizers.com\/wp-content\/uploads\/2024\/12\/0-methane-gas-6.webp” alt=”Powder automatic powder spraying and explosion suppression device” title_text=”0-methane gas 6″ _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}”][\/et_pb_image][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}”][et_pb_column type=”4_4″ _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}”][et_pb_text _builder_version=”4.27.4″ _module_preset=”default” header_3_text_color=”#0C71C3″ hover_enabled=”0″ global_colors_info=”{}” sticky_enabled=”0″]<\/p>\n

                            \u00a0Main Equipment \u2462 —<\/span>Powder automatic powder spraying and explosion suppression device<\/span><\/strong><\/h3>\n
                              \n
                            • Principle and Function:<\/strong>
                              The electric release device is mainly used to achieve emergency release of system pressure, installed at the beginning and end of the conveying pipeline, and focuses more on the protection of coal mine gas drainage stations and blending systems.<\/li>\n
                            • Installation requirements:<\/strong>
                              Installed on the end discharge pipe of the conveying pipeline and the outlet exhaust pipeline of the coal mine gas drainage station. A dry flame arrester should be installed at the rear end of the release valve to ensure that the released gas does not affect the pipeline;<\/li>\n<\/ul>\n

                              [\/et_pb_text][et_pb_image src=”https:\/\/regenerative-thermal-oxidizers.com\/wp-content\/uploads\/2024\/12\/0-methane-gas-7.webp” alt=”Water sealed fire and explosion prevention device
                              \n” title_text=”0-methane gas 7″ _builder_version=”4.27.4″ _module_preset=”default” global_colors_info=”{}”][\/et_pb_image][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=”4.27.4″ _module_preset=”default” column_structure=”2_5,3_5″ use_custom_gutter=”on” gutter_width=”1″ hover_enabled=”0″ sticky_enabled=”0″][et_pb_column _builder_version=”4.27.4″ _module_preset=”default” type=”2_5″][et_pb_text _builder_version=”4.27.4″ _module_preset=”default” header_3_text_color=”#0C71C3″ hover_enabled=”0″ global_colors_info=”{}” sticky_enabled=”0″]<\/p>\n

                              \u00a0Main Equipment \u2463 —Explosion prevention and venting device<\/span><\/strong><\/span><\/h3>\n
                                \n
                              • Adopting a combination of photoelectric flame sensors, pressure control sensors, and electromechanical linkage to control the action of the automatic explosion-proof device<\/li>\n
                              • Pay attention to the installation direction<\/li>\n<\/ul>\n

                                [\/et_pb_text][\/et_pb_column][et_pb_column _builder_version=”4.27.4″ _module_preset=”default” type=”3_5″][et_pb_image src=”https:\/\/regenerative-thermal-oxidizers.com\/wp-content\/uploads\/2024\/12\/0-methane-gas-8.webp” _builder_version=”4.27.4″ _module_preset=”default” alt=”methane gas” title_text=”0-methane gas 8″ hover_enabled=”0″ sticky_enabled=”0″][\/et_pb_image][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=”4.27.4″ _module_preset=”default” column_structure=”1_2,1_4,1_4″ hover_enabled=”0″ sticky_enabled=”0″ use_custom_gutter=”on” gutter_width=”1″][et_pb_column _builder_version=”4.27.4″ _module_preset=”default” type=”1_2″][et_pb_text _builder_version=”4.27.4″ _module_preset=”default” header_3_text_color=”#0C71C3″ hover_enabled=”0″ global_colors_info=”{}” sticky_enabled=”0″]<\/p>\n

                                \u00a0Main Equipment \u2464 —Dry flame arrester<\/span><\/strong><\/h3>\n
                                  \n
                                • Principle and Function:<\/strong>
                                  Dry flame arresters utilize the principle of flame quenching in narrow slits by bending and overlapping stainless steel plates to form a flame extinguishing layer with very small gaps. When a flame is generated in the pipeline, it will be blocked by a dry flame arrester, causing the flame to extinguish or reduce the intensity of the fire. Plays a hindering role in the spread of flames.
                                  There is a drain valve at the bottom, which needs to be opened regularly to prevent excessive water accumulation in the flame retardant core and affect its use.
                                  There are pressure gauges on both sides of the top flame retardant core to monitor whether the flame retardant core is blocked.<\/li>\n<\/ul>\n

                                  [\/et_pb_text][\/et_pb_column][et_pb_column _builder_version=”4.27.4″ _module_preset=”default” type=”1_4″][et_pb_image src=”https:\/\/regenerative-thermal-oxidizers.com\/wp-content\/uploads\/2024\/12\/0-dry-flame-arrester-2.webp” _builder_version=”4.27.4″ _module_preset=”default” alt=”dry flame arrester” title_text=”0-dry flame arrester 2″ hover_enabled=”0″ sticky_enabled=”0″][\/et_pb_image][\/et_pb_column][et_pb_column _builder_version=”4.27.4″ _module_preset=”default” type=”1_4″][et_pb_image src=”https:\/\/regenerative-thermal-oxidizers.com\/wp-content\/uploads\/2024\/12\/0-dry-flame-arrester-3.webp” _builder_version=”4.27.4″ _module_preset=”default” alt=”dry flame arrester” title_text=”0-dry flame arrester 3″ hover_enabled=”0″ sticky_enabled=”0″][\/et_pb_image][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=”4.27.4″ _module_preset=”default” column_structure=”2_5,3_5″ hover_enabled=”0″ sticky_enabled=”0″][et_pb_column _builder_version=”4.27.4″ _module_preset=”default” type=”2_5″][et_pb_image src=”https:\/\/regenerative-thermal-oxidizers.com\/wp-content\/uploads\/2024\/12\/0-Dehydrator-1.webp” _builder_version=”4.27.4″ _module_preset=”default” alt=”Dehydrator” title_text=”0-Dehydrator 1″ hover_enabled=”0″ sticky_enabled=”0″][\/et_pb_image][\/et_pb_column][et_pb_column _builder_version=”4.27.4″ _module_preset=”default” type=”3_5″][et_pb_text _builder_version=”4.27.4″ _module_preset=”default” header_3_text_color=”#0C71C3″ hover_enabled=”0″ global_colors_info=”{}” sticky_enabled=”0″]<\/p>\n

                                  \u00a0Main Equipment \u2465 —<\/span><\/strong>Dry flame arrester<\/span><\/strong><\/h3>\n
                                    \n
                                  • Principle and Function:<\/strong>
                                    The high-efficiency composite gas-liquid separator has multiple functions such as dehydration, dust removal, and pressure stabilization, and is a gas purification treatment equipment.
                                    Adopting cyclone separation technology, utilizing centrifugal force for gas-liquid separation. The separated water flows down along the cylinder wall, while the gas spirals up along the cylinder wall and enters the gas end through the secondary purification effect of the top separation layer, achieving the purification of the gas and meeting the gas indicators required by the gas engine.<\/li>\n<\/ul>\n

                                    [\/et_pb_text][\/et_pb_column][\/et_pb_row][\/et_pb_section][et_pb_section fb_built=”1″ theme_builder_area=”post_content” _builder_version=”4.27.4″ _module_preset=”default”][et_pb_row _builder_version=”4.27.4″ _module_preset=”default” theme_builder_area=”post_content”][et_pb_column _builder_version=”4.27.4″ _module_preset=”default” type=”4_4″ theme_builder_area=”post_content”][et_pb_text _builder_version=”4.27.4″ _module_preset=”default” theme_builder_area=”post_content” hover_enabled=”0″ sticky_enabled=”0″]<\/p>\n

                                    Mixing System<\/strong><\/h2>\n

                                    [\/et_pb_text][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=”4.27.4″ _module_preset=”default” column_structure=”1_3,1_3,1_3″ theme_builder_area=”post_content” use_custom_gutter=”on” gutter_width=”2″ hover_enabled=”0″ sticky_enabled=”0″][et_pb_column _builder_version=”4.27.4″ _module_preset=”default” type=”1_3″ theme_builder_area=”post_content”][et_pb_text _builder_version=”4.27.4″ _module_preset=”default” theme_builder_area=”post_content” hover_enabled=”0″ sticky_enabled=”0″]<\/p>\n

                                    Complex working conditions<\/strong><\/h3>\n

                                    1. Fluctuations in low concentration methane concentration
                                    2. Fluctuations in low concentration methane flow rate
                                    3. Temperature fluctuations of low concentration methane
                                    4. Low concentration methane pressure fluctuations
                                    5. Low concentration methane humidity fluctuations
                                    6. Fluctuations in Vam and Methane Concentrations<\/p>\n

                                    [\/et_pb_text][\/et_pb_column][et_pb_column _builder_version=”4.27.4″ _module_preset=”default” type=”1_3″ theme_builder_area=”post_content”][et_pb_text _builder_version=”4.27.4″ _module_preset=”default” theme_builder_area=”post_content” hover_enabled=”0″ sticky_enabled=”0″]<\/p>\n

                                    Research method<\/strong><\/h3>\n

                                    1. Research on Adaptive Fast Response Algorithm of Neural Network for Monitoring and Adjusting Input Parameters
                                    2. Research on Blender Design Based on Elastic Damping Principle
                                    3. CFD fluid calculation optimization of mixer structure<\/p>\n

                                    [\/et_pb_text][\/et_pb_column][et_pb_column _builder_version=”4.27.4″ _module_preset=”default” type=”1_3″ theme_builder_area=”post_content”][et_pb_text _builder_version=”4.27.4″ _module_preset=”default” theme_builder_area=”post_content” hover_enabled=”0″ sticky_enabled=”0″]<\/p>\n

                                    Response output<\/strong><\/h3>\n

                                    1. The fluctuation range of gas concentration after blending is 1.2% \u00b1 0.1%
                                    2. Instantaneous fluctuation of concentration within 10%
                                    3. Instantaneous response within 1 second<\/p>\n

                                    [\/et_pb_text][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=”4.27.4″ _module_preset=”default” column_structure=”1_3,1_3,1_3″ theme_builder_area=”post_content” use_custom_gutter=”on” gutter_width=”2″ hover_enabled=”0″ sticky_enabled=”0″][et_pb_column _builder_version=”4.27.4″ _module_preset=”default” type=”1_3″ theme_builder_area=”post_content”][et_pb_image src=”https:\/\/regenerative-thermal-oxidizers.com\/wp-content\/uploads\/2024\/12\/0-Methane-concentration-monitoring-equipment.webp” _builder_version=”4.27.4″ _module_preset=”default” theme_builder_area=”post_content” alt=”Methane concentration monitoring equipment” title_text=”0-Methane concentration monitoring equipment” hover_enabled=”0″ sticky_enabled=”0″][\/et_pb_image][\/et_pb_column][et_pb_column _builder_version=”4.27.4″ _module_preset=”default” type=”1_3″ theme_builder_area=”post_content”][et_pb_image src=”https:\/\/regenerative-thermal-oxidizers.com\/wp-content\/uploads\/2024\/12\/0-Mixing-system-1.webp” _builder_version=”4.27.4″ _module_preset=”default” theme_builder_area=”post_content” alt=”Mixing system” title_text=”0-Mixing system 1″ hover_enabled=”0″ sticky_enabled=”0″][\/et_pb_image][\/et_pb_column][et_pb_column _builder_version=”4.27.4″ _module_preset=”default” type=”1_3″ theme_builder_area=”post_content”][et_pb_image src=”https:\/\/regenerative-thermal-oxidizers.com\/wp-content\/uploads\/2024\/12\/0-Mixing-system-2.webp” _builder_version=”4.27.4″ _module_preset=”default” theme_builder_area=”post_content” alt=”Mixing system” title_text=”0-Mixing system 2″ hover_enabled=”0″ sticky_enabled=”0″][\/et_pb_image][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=”4.27.4″ _module_preset=”default” theme_builder_area=”post_content”][et_pb_column _builder_version=”4.27.4″ _module_preset=”default” type=”4_4″ theme_builder_area=”post_content”][et_pb_text _builder_version=”4.27.4″ _module_preset=”default” theme_builder_area=”post_content” hover_enabled=”0″ sticky_enabled=”0″]<\/p>\n

                                    Blender – Simulation Analysis<\/h3>\n

                                    [\/et_pb_text][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=”4.27.4″ _module_preset=”default” column_structure=”2_3,1_3″ theme_builder_area=”post_content” hover_enabled=”0″ sticky_enabled=”0″][et_pb_column _builder_version=”4.27.4″ _module_preset=”default” type=”2_3″ theme_builder_area=”post_content”][et_pb_image src=”https:\/\/regenerative-thermal-oxidizers.com\/wp-content\/uploads\/2024\/12\/0-Time-dependent-curve-of-export-concentration.webp” _builder_version=”4.27.4″ _module_preset=”default” theme_builder_area=”post_content” alt=”Time dependent curve of export concentration” title_text=”0-Time dependent curve of export concentration” hover_enabled=”0″ sticky_enabled=”0″][\/et_pb_image][et_pb_text _builder_version=”4.27.4″ _module_preset=”default” theme_builder_area=”post_content” hover_enabled=”0″ sticky_enabled=”0″]<\/p>\n

                                    As can be seen from the above figure, the outlet concentration gradually increases with time and stabilizes at 1.2% at 3 seconds. The cloud map on the right shows the variation of outlet concentration with time.<\/p>\n

                                    [\/et_pb_text][\/et_pb_column][et_pb_column _builder_version=”4.27.4″ _module_preset=”default” type=”1_3″ theme_builder_area=”post_content”][et_pb_image src=”https:\/\/regenerative-thermal-oxidizers.com\/wp-content\/uploads\/2024\/12\/0-Time-dependent-curve-of-export-concentration-2.webp” _builder_version=”4.27.4″ _module_preset=”default” theme_builder_area=”post_content” alt=”Time dependent curve of export concentration” title_text=”0-Time dependent curve of export concentration 2″ hover_enabled=”0″ sticky_enabled=”0″][\/et_pb_image][\/et_pb_column][\/et_pb_row][\/et_pb_section][et_pb_section fb_built=”1″ theme_builder_area=”post_content” _builder_version=”4.27.4″ _module_preset=”default”][\/et_pb_section]<\/p>","protected":false},"excerpt":{"rendered":"

                                    Discover how our advanced RTO systems enable efficient reuse of low-concentration gases, reducing emissions and lowering costs. Optimize your processes with sustainable, high-performance solutions today.Current Situation of Low Concentration Methane UtilizationLow concentration methane has a large emission volume In 2018, the global coal mine methane leakage was 40 million tons, equivalent to the emission of […]<\/p>","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_et_pb_use_builder":"on","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"class_list":["post-4229","page","type-page","status-publish","hentry"],"rankMath":{"parentDomain":"regenerative-thermal-oxidizers.com","noFollowDomains":[],"noFollowExcludeDomains":[],"noFollowExternalLinks":false,"featuredImageNotice":"\u0417\u043e\u0431\u0440\u0430\u0436\u0435\u043d\u043d\u044f \u043c\u0430\u0454 \u0431\u0443\u0442\u0438 \u043d\u0435 \u043c\u0435\u043d\u0448\u0435 200 \u043d\u0430 200 \u043f\u0456\u043a\u0441\u0435\u043b\u0456\u0432, \u0449\u043e\u0431 \u0439\u043e\u0433\u043e \u043c\u043e\u0433\u043b\u0438 \u043f\u043e\u043a\u0430\u0437\u0443\u0432\u0430\u0442\u0438 Facebook \u0442\u0430 \u0456\u043d\u0448\u0456 \u0441\u0430\u0439\u0442\u0438 \u0441\u043e\u0446\u0456\u0430\u043b\u044c\u043d\u0438\u0445 \u043c\u0435\u0440\u0435\u0436.","pluginReviewed":false,"postSettings":{"linkSuggestions":true,"useFocusKeyword":false},"frontEndScore":false,"postName":"reusing-low-concentration-methane-gas","permalinkFormat":"https:\/\/regenerative-thermal-oxidizers.com\/uk\/%pagename%\/","showLockModifiedDate":true,"assessor":{"focusKeywordLink":"https:\/\/regenerative-thermal-oxidizers.com\/wp-admin\/edit.php?focus_keyword=%focus_keyword%&post_type=%post_type%","hasTOCPlugin":{"stackable-ultimate-gutenberg-blocks\/plugin.php":"Stackable"},"primaryTaxonomy":false,"serpData":{"title":"","description":"","focusKeywords":"","pillarContent":false,"canonicalUrl":"","breadcrumbTitle":"","advancedRobots":{"max-snippet":"-1","max-video-preview":"-1","max-image-preview":"large"},"facebookTitle":"","facebookDescription":"","facebookImage":"","facebookImageID":"","facebookHasOverlay":false,"facebookImageOverlay":"","facebookAuthor":"","twitterCardType":"","twitterUseFacebook":true,"twitterTitle":"","twitterDescription":"","twitterImage":"","twitterImageID":"","twitterHasOverlay":false,"twitterImageOverlay":"","twitterPlayerUrl":"","twitterPlayerSize":"","twitterPlayerStream":"","twitterPlayerStreamCtype":"","twitterAppDescription":"","twitterAppIphoneName":"","twitterAppIphoneID":"","twitterAppIphoneUrl":"","twitterAppIpadName":"","twitterAppIpadID":"","twitterAppIpadUrl":"","twitterAppGoogleplayName":"","twitterAppGoogleplayID":"","twitterAppGoogleplayUrl":"","twitterAppCountry":"","robots":{"index":true},"twitterAuthor":"\u0456\u043c'\u044f \u043a\u043e\u0440\u0438\u0441\u0442\u0443\u0432\u0430\u0447\u0430","primaryTerm":0,"authorName":"rtoadmin","titleTemplate":"Singapore %title% Supplier Solution%sep% %sitename%","descriptionTemplate":"%excerpt%","showScoreFrontend":true,"lockModifiedDate":false},"powerWords":[],"diacritics":{"A":"[\\u0041\\u24B6\\uFF21\\u00C0\\u00C1\\u00C2\\u1EA6\\u1EA4\\u1EAA\\u1EA8\\u00C3\\u0100\\u0102\\u1EB0\\u1EAE\\u1EB4\\u1EB2\\u0226\\u01E0\\u00C4\\u01DE\\u1EA2\\u00C5\\u01FA\\u01CD\\u0200\\u0202\\u1EA0\\u1EAC\\u1EB6\\u1E00\\u0104\\u023A\\u2C6F]","AA":"[\\uA732]","AE":"[\\u00C6\\u01FC\\u01E2]","AO":"[\\uA734]","AU":"[\\uA736]","AV":"[\\uA738\\uA73A]","AY":"[\\uA73C]","B":"[\\u0042\\u24B7\\uFF22\\u1E02\\u1E04\\u1E06\\u0243\\u0182\\u0181]","C":"[\\u0043\\u24B8\\uFF23\\u0106\\u0108\\u010A\\u010C\\u00C7\\u1E08\\u0187\\u023B\\uA73E]","D":"[\\u0044\\u24B9\\uFF24\\u1E0A\\u010E\\u1E0C\\u1E10\\u1E12\\u1E0E\\u0110\\u018B\\u018A\\u0189\\uA779]","DZ":"[\\u01F1\\u01C4]","Dz":"[\\u01F2\\u01C5]","E":"[\\u0045\\u24BA\\uFF25\\u00C8\\u00C9\\u00CA\\u1EC0\\u1EBE\\u1EC4\\u1EC2\\u1EBC\\u0112\\u1E14\\u1E16\\u0114\\u0116\\u00CB\\u1EBA\\u011A\\u0204\\u0206\\u1EB8\\u1EC6\\u0228\\u1E1C\\u0118\\u1E18\\u1E1A\\u0190\\u018E]","F":"[\\u0046\\u24BB\\uFF26\\u1E1E\\u0191\\uA77B]","G":"[\\u0047\\u24BC\\uFF27\\u01F4\\u011C\\u1E20\\u011E\\u0120\\u01E6\\u0122\\u01E4\\u0193\\uA7A0\\uA77D\\uA77E]","H":"[\\u0048\\u24BD\\uFF28\\u0124\\u1E22\\u1E26\\u021E\\u1E24\\u1E28\\u1E2A\\u0126\\u2C67\\u2C75\\uA78D]","I":"[\\u0049\\u24BE\\uFF29\\u00CC\\u00CD\\u00CE\\u0128\\u012A\\u012C\\u0130\\u00CF\\u1E2E\\u1EC8\\u01CF\\u0208\\u020A\\u1ECA\\u012E\\u1E2C\\u0197]","J":"[\\u004A\\u24BF\\uFF2A\\u0134\\u0248]","K":"[\\u004B\\u24C0\\uFF2B\\u1E30\\u01E8\\u1E32\\u0136\\u1E34\\u0198\\u2C69\\uA740\\uA742\\uA744\\uA7A2]","L":"[\\u004C\\u24C1\\uFF2C\\u013F\\u0139\\u013D\\u1E36\\u1E38\\u013B\\u1E3C\\u1E3A\\u0141\\u023D\\u2C62\\u2C60\\uA748\\uA746\\uA780]","LJ":"[\\u01C7]","Lj":"[\\u01C8]","M":"[\\u004D\\u24C2\\uFF2D\\u1E3E\\u1E40\\u1E42\\u2C6E\\u019C]","N":"[\\u004E\\u24C3\\uFF2E\\u01F8\\u0143\\u00D1\\u1E44\\u0147\\u1E46\\u0145\\u1E4A\\u1E48\\u0220\\u019D\\uA790\\uA7A4]","NJ":"[\\u01CA]","Nj":"[\\u01CB]","O":"[\\u004F\\u24C4\\uFF2F\\u00D2\\u00D3\\u00D4\\u1ED2\\u1ED0\\u1ED6\\u1ED4\\u00D5\\u1E4C\\u022C\\u1E4E\\u014C\\u1E50\\u1E52\\u014E\\u022E\\u0230\\u00D6\\u022A\\u1ECE\\u0150\\u01D1\\u020C\\u020E\\u01A0\\u1EDC\\u1EDA\\u1EE0\\u1EDE\\u1EE2\\u1ECC\\u1ED8\\u01EA\\u01EC\\u00D8\\u01FE\\u0186\\u019F\\uA74A\\uA74C]","OI":"[\\u01A2]","OO":"[\\uA74E]","OU":"[\\u0222]","P":"[\\u0050\\u24C5\\uFF30\\u1E54\\u1E56\\u01A4\\u2C63\\uA750\\uA752\\uA754]","Q":"[\\u0051\\u24C6\\uFF31\\uA756\\uA758\\u024A]","R":"[\\u0052\\u24C7\\uFF32\\u0154\\u1E58\\u0158\\u0210\\u0212\\u1E5A\\u1E5C\\u0156\\u1E5E\\u024C\\u2C64\\uA75A\\uA7A6\\uA782]","S":"[\\u0053\\u24C8\\uFF33\\u1E9E\\u015A\\u1E64\\u015C\\u1E60\\u0160\\u1E66\\u1E62\\u1E68\\u0218\\u015E\\u2C7E\\uA7A8\\uA784]","T":"[\\u0054\\u24C9\\uFF34\\u1E6A\\u0164\\u1E6C\\u021A\\u0162\\u1E70\\u1E6E\\u0166\\u01AC\\u01AE\\u023E\\uA786]","TZ":"[\\uA728]","U":"[\\u0055\\u24CA\\uFF35\\u00D9\\u00DA\\u00DB\\u0168\\u1E78\\u016A\\u1E7A\\u016C\\u00DC\\u01DB\\u01D7\\u01D5\\u01D9\\u1EE6\\u016E\\u0170\\u01D3\\u0214\\u0216\\u01AF\\u1EEA\\u1EE8\\u1EEE\\u1EEC\\u1EF0\\u1EE4\\u1E72\\u0172\\u1E76\\u1E74\\u0244]","V":"[\\u0056\\u24CB\\uFF36\\u1E7C\\u1E7E\\u01B2\\uA75E\\u0245]","VY":"[\\uA760]","W":"[\\u0057\\u24CC\\uFF37\\u1E80\\u1E82\\u0174\\u1E86\\u1E84\\u1E88\\u2C72]","X":"[\\u0058\\u24CD\\uFF38\\u1E8A\\u1E8C]","Y":"[\\u0059\\u24CE\\uFF39\\u1EF2\\u00DD\\u0176\\u1EF8\\u0232\\u1E8E\\u0178\\u1EF6\\u1EF4\\u01B3\\u024E\\u1EFE]","Z":"[\\u005A\\u24CF\\uFF3A\\u0179\\u1E90\\u017B\\u017D\\u1E92\\u1E94\\u01B5\\u0224\\u2C7F\\u2C6B\\uA762]","a":"[\\u0061\\u24D0\\uFF41\\u1E9A\\u00E0\\u00E1\\u00E2\\u1EA7\\u1EA5\\u1EAB\\u1EA9\\u00E3\\u0101\\u0103\\u1EB1\\u1EAF\\u1EB5\\u1EB3\\u0227\\u01E1\\u00E4\\u01DF\\u1EA3\\u00E5\\u01FB\\u01CE\\u0201\\u0203\\u1EA1\\u1EAD\\u1EB7\\u1E01\\u0105\\u2C65\\u0250]","aa":"[\\uA733]","ae":"[\\u00E6\\u01FD\\u01E3]","ao":"[\\uA735]","au":"[\\uA737]","av":"[\\uA739\\uA73B]","ay":"[\\uA73D]","b":"[\\u0062\\u24D1\\uFF42\\u1E03\\u1E05\\u1E07\\u0180\\u0183\\u0253]","c":"[\\u0063\\u24D2\\uFF43\\u0107\\u0109\\u010B\\u010D\\u00E7\\u1E09\\u0188\\u023C\\uA73F\\u2184]","d":"[\\u0064\\u24D3\\uFF44\\u1E0B\\u010F\\u1E0D\\u1E11\\u1E13\\u1E0F\\u0111\\u018C\\u0256\\u0257\\uA77A]","dz":"[\\u01F3\\u01C6]","e":"[\\u0065\\u24D4\\uFF45\\u00E8\\u00E9\\u00EA\\u1EC1\\u1EBF\\u1EC5\\u1EC3\\u1EBD\\u0113\\u1E15\\u1E17\\u0115\\u0117\\u00EB\\u1EBB\\u011B\\u0205\\u0207\\u1EB9\\u1EC7\\u0229\\u1E1D\\u0119\\u1E19\\u1E1B\\u0247\\u025B\\u01DD]","f":"[\\u0066\\u24D5\\uFF46\\u1E1F\\u0192\\uA77C]","g":"[\\u0067\\u24D6\\uFF47\\u01F5\\u011D\\u1E21\\u011F\\u0121\\u01E7\\u0123\\u01E5\\u0260\\uA7A1\\u1D79\\uA77F]","h":"[\\u0068\\u24D7\\uFF48\\u0125\\u1E23\\u1E27\\u021F\\u1E25\\u1E29\\u1E2B\\u1E96\\u0127\\u2C68\\u2C76\\u0265]","hv":"[\\u0195]","i":"[\\u0069\\u24D8\\uFF49\\u00EC\\u00ED\\u00EE\\u0129\\u012B\\u012D\\u00EF\\u1E2F\\u1EC9\\u01D0\\u0209\\u020B\\u1ECB\\u012F\\u1E2D\\u0268\\u0131]","j":"[\\u006A\\u24D9\\uFF4A\\u0135\\u01F0\\u0249]","k":"[\\u006B\\u24DA\\uFF4B\\u1E31\\u01E9\\u1E33\\u0137\\u1E35\\u0199\\u2C6A\\uA741\\uA743\\uA745\\uA7A3]","l":"[\\u006C\\u24DB\\uFF4C\\u0140\\u013A\\u013E\\u1E37\\u1E39\\u013C\\u1E3D\\u1E3B\\u017F\\u0142\\u019A\\u026B\\u2C61\\uA749\\uA781\\uA747]","lj":"[\\u01C9]","m":"[\\u006D\\u24DC\\uFF4D\\u1E3F\\u1E41\\u1E43\\u0271\\u026F]","n":"[\\u006E\\u24DD\\uFF4E\\u01F9\\u0144\\u00F1\\u1E45\\u0148\\u1E47\\u0146\\u1E4B\\u1E49\\u019E\\u0272\\u0149\\uA791\\uA7A5]","nj":"[\\u01CC]","o":"[\\u006F\\u24DE\\uFF4F\\u00F2\\u00F3\\u00F4\\u1ED3\\u1ED1\\u1ED7\\u1ED5\\u00F5\\u1E4D\\u022D\\u1E4F\\u014D\\u1E51\\u1E53\\u014F\\u022F\\u0231\\u00F6\\u022B\\u1ECF\\u0151\\u01D2\\u020D\\u020F\\u01A1\\u1EDD\\u1EDB\\u1EE1\\u1EDF\\u1EE3\\u1ECD\\u1ED9\\u01EB\\u01ED\\u00F8\\u01FF\\u0254\\uA74B\\uA74D\\u0275]","oi":"[\\u01A3]","ou":"[\\u0223]","oo":"[\\uA74F]","p":"[\\u0070\\u24DF\\uFF50\\u1E55\\u1E57\\u01A5\\u1D7D\\uA751\\uA753\\uA755]","q":"[\\u0071\\u24E0\\uFF51\\u024B\\uA757\\uA759]","r":"[\\u0072\\u24E1\\uFF52\\u0155\\u1E59\\u0159\\u0211\\u0213\\u1E5B\\u1E5D\\u0157\\u1E5F\\u024D\\u027D\\uA75B\\uA7A7\\uA783]","s":"[\\u0073\\u24E2\\uFF53\\u015B\\u1E65\\u015D\\u1E61\\u0161\\u1E67\\u1E63\\u1E69\\u0219\\u015F\\u023F\\uA7A9\\uA785\\u1E9B]","ss":"[\\u00DF]","t":"[\\u0074\\u24E3\\uFF54\\u1E6B\\u1E97\\u0165\\u1E6D\\u021B\\u0163\\u1E71\\u1E6F\\u0167\\u01AD\\u0288\\u2C66\\uA787]","tz":"[\\uA729]","u":"[\\u0075\\u24E4\\uFF55\\u00F9\\u00FA\\u00FB\\u0169\\u1E79\\u016B\\u1E7B\\u016D\\u00FC\\u01DC\\u01D8\\u01D6\\u01DA\\u1EE7\\u016F\\u0171\\u01D4\\u0215\\u0217\\u01B0\\u1EEB\\u1EE9\\u1EEF\\u1EED\\u1EF1\\u1EE5\\u1E73\\u0173\\u1E77\\u1E75\\u0289]","v":"[\\u0076\\u24E5\\uFF56\\u1E7D\\u1E7F\\u028B\\uA75F\\u028C]","vy":"[\\uA761]","w":"[\\u0077\\u24E6\\uFF57\\u1E81\\u1E83\\u0175\\u1E87\\u1E85\\u1E98\\u1E89\\u2C73]","x":"[\\u0078\\u24E7\\uFF58\\u1E8B\\u1E8D]","y":"[\\u0079\\u24E8\\uFF59\\u1EF3\\u00FD\\u0177\\u1EF9\\u0233\\u1E8F\\u00FF\\u1EF7\\u1E99\\u1EF5\\u01B4\\u024F\\u1EFF]","z":"[\\u007A\\u24E9\\uFF5A\\u017A\\u1E91\\u017C\\u017E\\u1E93\\u1E95\\u01B6\\u0225\\u0240\\u2C6C\\uA763]"},"researchesTests":["contentHasTOC","contentHasShortParagraphs","contentHasAssets","keywordInTitle","keywordInMetaDescription","keywordInPermalink","keywordIn10Percent","keywordInContent","keywordInSubheadings","keywordInImageAlt","keywordDensity","keywordNotUsed","lengthContent","lengthPermalink","linksHasInternal","linksHasExternals","linksNotAllExternals","titleStartWithKeyword","titleSentiment","titleHasPowerWords","titleHasNumber","hasContentAI"],"hasRedirection":false,"hasBreadcrumb":false},"homeUrl":"https:\/\/regenerative-thermal-oxidizers.com\/uk","objectID":4229,"objectType":"post","locale":"uk","localeFull":"uk","overlayImages":{"play":{"name":"\u0406\u043a\u043e\u043d\u043a\u0430 PLAY","url":"https:\/\/regenerative-thermal-oxidizers.com\/wp-content\/plugins\/seo-by-rank-math\/assets\/admin\/img\/icon-play.png","path":"\/var\/www\/html\/public_html\/wp-content\/plugins\/seo-by-rank-math\/assets\/admin\/img\/icon-play.png","position":"middle_center"},"gif":{"name":"GIF \u0437\u043d\u0430\u0447\u043e\u043a","url":"https:\/\/regenerative-thermal-oxidizers.com\/wp-content\/plugins\/seo-by-rank-math\/assets\/admin\/img\/icon-gif.png","path":"\/var\/www\/html\/public_html\/wp-content\/plugins\/seo-by-rank-math\/assets\/admin\/img\/icon-gif.png","position":"middle_center"}},"defautOgImage":"https:\/\/regenerative-thermal-oxidizers.com\/wp-content\/plugins\/seo-by-rank-math\/assets\/admin\/img\/social-placeholder.jpg","customPermalinks":true,"isUserRegistered":false,"autoSuggestKeywords":false,"connectSiteUrl":"https:\/\/rankmath.com\/auth?site=https%3A%2F%2Fregenerative-thermal-oxidizers.com%2Fuk&r=https%3A%2F%2Fregenerative-thermal-oxidizers.com%2Fuk%2Fwp-json%2Fwp%2Fv2%2Fpages%2F4229%3Fnonce%3Dd44e8b8dcc","maxTags":5,"trendsIcon":"<\/svg>","showScore":true,"siteFavIcon":"https:\/\/regenerative-thermal-oxidizers.com\/wp-content\/uploads\/2022\/11\/cropped-rto-icon-32x32.png","canUser":{"general":false,"advanced":false,"snippet":false,"social":false,"analysis":false,"analytics":false,"content_ai":false},"showKeywordIntent":true,"isPro":false,"is_front_page":false,"trendsUpgradeLink":"https:\/\/rankmath.com\/pricing\/?utm_source=Plugin&utm_medium=CE%20General%20Tab%20Trends&utm_campaign=WP","trendsUpgradeLabel":"\u041e\u043d\u043e\u0432\u043b\u0435\u043d\u043d\u044f","trendsPreviewImage":"https:\/\/regenerative-thermal-oxidizers.com\/wp-content\/plugins\/seo-by-rank-math\/assets\/admin\/img\/trends-preview.jpg","currentEditor":false,"homepageData":{"assessor":{"powerWords":[],"diacritics":true,"researchesTests":["contentHasTOC","contentHasShortParagraphs","contentHasAssets","keywordInTitle","keywordInMetaDescription","keywordInPermalink","keywordIn10Percent","keywordInContent","keywordInSubheadings","keywordInImageAlt","keywordDensity","keywordNotUsed","lengthContent","lengthPermalink","linksHasInternal","linksHasExternals","linksNotAllExternals","titleStartWithKeyword","titleSentiment","titleHasPowerWords","titleHasNumber","hasContentAI"],"hasBreadcrumb":false,"serpData":{"title":"1TP2\u041d\u0430\u0437\u0432\u0430\u0422\u0438\u0442\u0443% %\u0441\u0442\u043e\u0440\u0456\u043d\u043a\u0430% 1TP2\u0422\u0435\u043f% 1TP2\u041e\u043f\u0438\u0441\u0422\u0438\u0442\u0443%","description":"","titleTemplate":"%sitename% %page% %sep% %sitedesc%","descriptionTemplate":"","focusKeywords":"","breadcrumbTitle":"Home","robots":{"index":true},"advancedRobots":{"max-snippet":"-1","max-video-preview":"-1","max-image-preview":"large"},"facebookTitle":"","facebookDescription":"","facebookImage":"","facebookImageID":""}}},"tocTitle":"Table of Contents","tocExcludeHeadings":[],"listStyle":"ul"},"_links":{"self":[{"href":"https:\/\/regenerative-thermal-oxidizers.com\/uk\/wp-json\/wp\/v2\/pages\/4229","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/regenerative-thermal-oxidizers.com\/uk\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/regenerative-thermal-oxidizers.com\/uk\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/regenerative-thermal-oxidizers.com\/uk\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/regenerative-thermal-oxidizers.com\/uk\/wp-json\/wp\/v2\/comments?post=4229"}],"version-history":[{"count":37,"href":"https:\/\/regenerative-thermal-oxidizers.com\/uk\/wp-json\/wp\/v2\/pages\/4229\/revisions"}],"predecessor-version":[{"id":4297,"href":"https:\/\/regenerative-thermal-oxidizers.com\/uk\/wp-json\/wp\/v2\/pages\/4229\/revisions\/4297"}],"wp:attachment":[{"href":"https:\/\/regenerative-thermal-oxidizers.com\/uk\/wp-json\/wp\/v2\/media?parent=4229"}],"curies":[{"name":"\u0412\u041f","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}