{"id":2906,"date":"2024-10-25T03:07:31","date_gmt":"2024-10-25T03:07:31","guid":{"rendered":"https:\/\/regenerative-thermal-oxidizers.com\/?page_id=2906"},"modified":"2024-10-30T09:33:42","modified_gmt":"2024-10-30T09:33:42","slug":"rto-for-coating-industry","status":"publish","type":"page","link":"https:\/\/regenerative-thermal-oxidizers.com\/pt\/rto-for-coating-industry\/","title":{"rendered":"RTO para Ind\u00fastria de Revestimentos"},"content":{"rendered":"
[et_pb_section fb_built=”1″ fullwidth=”on” _builder_version=”4.27.0″ _module_preset=”default” global_colors_info=”{}”][et_pb_fullwidth_header title=”Regenerative Thermal Oxidizer (RTO) for Coating Industry” button_one_text=”Click Here” _builder_version=”4.27.0″ _module_preset=”default” global_colors_info=”{}”][\/et_pb_fullwidth_header][\/et_pb_section][et_pb_section fb_built=”1″ _builder_version=”4.27.0″ _module_preset=”default” global_colors_info=”{}”][et_pb_row _builder_version=”4.27.0″ _module_preset=”default” global_colors_info=”{}”][et_pb_column type=”4_4″ _builder_version=”4.27.0″ _module_preset=”default” global_colors_info=”{}”][et_pb_text _builder_version=”4.27.0″ _module_preset=”default” header_2_font=”Arial|800|||||||” header_2_text_align=”center” global_colors_info=”{}”]<\/p>\n
[\/et_pb_text][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=”4.27.0″ _module_preset=”default” global_colors_info=”{}”][et_pb_column type=”4_4″ _builder_version=”4.27.0″ _module_preset=”default” global_colors_info=”{}”][et_pb_image src=”https:\/\/regenerative-thermal-oxidizers.com\/wp-content\/uploads\/2024\/10\/0-RT-solutions-for-coating-industry-1.webp” alt=”RT solutions for coating industry” title_text=”0-RT solutions for coating industry 1″ _builder_version=”4.27.0″ _module_preset=”default” global_colors_info=”{}”][\/et_pb_image][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=”4.27.0″ _module_preset=”default” global_colors_info=”{}”][et_pb_column type=”4_4″ _builder_version=”4.27.0″ _module_preset=”default” global_colors_info=”{}”][et_pb_text _builder_version=”4.27.0″ _module_preset=”default” global_colors_info=”{}”]<\/p>\n
[\/et_pb_text][et_pb_image src=”https:\/\/regenerative-thermal-oxidizers.com\/wp-content\/uploads\/2024\/10\/0-RTO-solutions-for-coating-industry-4-2.webp” alt=”RTO solutions for coating industry” title_text=”0-RTO solutions for coating industry 4 (2)” _builder_version=”4.27.0″ _module_preset=”default” global_colors_info=”{}”][\/et_pb_image][\/et_pb_column][\/et_pb_row][\/et_pb_section][et_pb_section fb_built=”1″ theme_builder_area=”post_content” _builder_version=”4.27.0″ _module_preset=”default”][et_pb_row _builder_version=”4.27.0″ _module_preset=”default” global_colors_info=”{}” theme_builder_area=”post_content”][et_pb_column type=”4_4″ _builder_version=”4.27.0″ _module_preset=”default” global_colors_info=”{}” theme_builder_area=”post_content”][et_pb_text _builder_version=”4.27.0″ _module_preset=”default” header_2_font=”Arial|800|||||||” header_2_text_align=”center” hover_enabled=”0″ global_colors_info=”{}” theme_builder_area=”post_content” sticky_enabled=”0″]<\/p>\n
[\/et_pb_text][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=”4.27.0″ _module_preset=”default” theme_builder_area=”post_content” use_custom_gutter=”on” gutter_width=”2″ hover_enabled=”0″ sticky_enabled=”0″][et_pb_column _builder_version=”4.27.0″ _module_preset=”default” type=”4_4″ theme_builder_area=”post_content”][et_pb_text _builder_version=”4.27.0″ _module_preset=”default” theme_builder_area=”post_content” hover_enabled=”0″ sticky_enabled=”0″]<\/p>\n
Os gases de exaust\u00e3o de baixa concentra\u00e7\u00e3o do forno traseiro s\u00e3o enviados para a entrada de ar fresco do forno frontal como ar fresco e geralmente n\u00e3o passam para os primeiros 2 ou 3 fornos de alta concentra\u00e7\u00e3o. Este m\u00e9todo pode reduzir o volume de exaust\u00e3o da m\u00e1quina de revestimento.<\/p>\n
[\/et_pb_text][et_pb_image src=”https:\/\/regenerative-thermal-oxidizers.com\/wp-content\/uploads\/2024\/10\/0-RTO-solutions-Coating-machine-wind-reduction-1.webp” _builder_version=”4.27.0″ _module_preset=”default” theme_builder_area=”post_content” alt=”RTO solutions Coating machine wind reduction” title_text=”0-RTO solutions Coating machine wind reduction 1″ hover_enabled=”0″ sticky_enabled=”0″][\/et_pb_image][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=”4.27.0″ _module_preset=”default” theme_builder_area=”post_content” use_custom_gutter=”on” gutter_width=”2″ hover_enabled=”0″ sticky_enabled=”0″][et_pb_column _builder_version=”4.27.0″ _module_preset=”default” type=”4_4″ theme_builder_area=”post_content”][et_pb_text _builder_version=”4.27.0″ _module_preset=”default” theme_builder_area=”post_content” hover_enabled=”0″ sticky_enabled=”0″]<\/p>\n
O g\u00e1s de exaust\u00e3o de baixa concentra\u00e7\u00e3o da cabe\u00e7a de revestimento\/sala de prepara\u00e7\u00e3o de cola \u00e9 enviado para a entrada de ar fresco do forno por um ventilador e utilizado como ar fresco para o forno (geralmente n\u00e3o passa para os fornos de alta concentra\u00e7\u00e3o nas duas primeiras se\u00e7\u00f5es). Este m\u00e9todo pode reduzir o volume de exaust\u00e3o da cabe\u00e7a de revestimento e da sala de prepara\u00e7\u00e3o de cola, evitando que o g\u00e1s de exaust\u00e3o de baixa concentra\u00e7\u00e3o entre no RTO e dilua a concentra\u00e7\u00e3o total.<\/p>\n
[\/et_pb_text][et_pb_image src=”https:\/\/regenerative-thermal-oxidizers.com\/wp-content\/uploads\/2024\/10\/0-RTO-solutions-for-coating-industry-5-1.webp” _builder_version=”4.27.0″ _module_preset=”default” theme_builder_area=”post_content” alt=”RTO solutions for coating industry” title_text=”0-RTO solutions for coating industry 5″ hover_enabled=”0″ sticky_enabled=”0″][\/et_pb_image][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=”4.27.0″ _module_preset=”default” theme_builder_area=”post_content” use_custom_gutter=”on” gutter_width=”2″ hover_enabled=”0″ sticky_enabled=”0″][et_pb_column _builder_version=”4.27.0″ _module_preset=”default” type=”4_4″ theme_builder_area=”post_content”][et_pb_text _builder_version=”4.27.0″ _module_preset=”default” theme_builder_area=”post_content” hover_enabled=”0″ sticky_enabled=”0″]<\/p>\n
[\/et_pb_text][et_pb_image src=”https:\/\/regenerative-thermal-oxidizers.com\/wp-content\/uploads\/2024\/10\/0-RTO-solutions-for-coating-industry-6-1.webp” _builder_version=”4.27.0″ _module_preset=”default” theme_builder_area=”post_content” alt=”RTO solutions for coating industry” title_text=”0-RTO solutions for coating industry 6″ hover_enabled=”0″ sticky_enabled=”0″][\/et_pb_image][\/et_pb_column][\/et_pb_row][\/et_pb_section][et_pb_section fb_built=”1″ theme_builder_area=”post_content” _builder_version=”4.27.0″ _module_preset=”default”][et_pb_row _builder_version=”4.27.0″ _module_preset=”default” global_colors_info=”{}” theme_builder_area=”post_content”][et_pb_column type=”4_4″ _builder_version=”4.27.0″ _module_preset=”default” global_colors_info=”{}” theme_builder_area=”post_content”][et_pb_text _builder_version=”4.27.0″ _module_preset=”default” header_2_font=”Arial|800|||||||” header_2_text_align=”center” hover_enabled=”0″ global_colors_info=”{}” theme_builder_area=”post_content” sticky_enabled=”0″]<\/p>\n
[\/et_pb_text][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=”4.27.0″ _module_preset=”default” theme_builder_area=”post_content”][et_pb_column _builder_version=”4.27.0″ _module_preset=”default” type=”4_4″ theme_builder_area=”post_content”][et_pb_text _builder_version=”4.27.0″ _module_preset=”default” theme_builder_area=”post_content” hover_enabled=”0″ sticky_enabled=”0″]<\/p>\n
[\/et_pb_text][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=”4.27.0″ _module_preset=”default” column_structure=”3_5,2_5″ theme_builder_area=”post_content” hover_enabled=”0″ sticky_enabled=”0″][et_pb_column _builder_version=”4.27.0″ _module_preset=”default” type=”3_5″ theme_builder_area=”post_content”][et_pb_image src=”https:\/\/regenerative-thermal-oxidizers.com\/wp-content\/uploads\/2024\/10\/0-Waste-heat-recovery-coating-industry-1.webp” _builder_version=”4.27.0″ _module_preset=”default” theme_builder_area=”post_content” alt=”Waste heat recovery coating industry ” title_text=”0-Waste heat recovery coating industry 1″ hover_enabled=”0″ sticky_enabled=”0″][\/et_pb_image][\/et_pb_column][et_pb_column _builder_version=”4.27.0″ _module_preset=”default” type=”2_5″ theme_builder_area=”post_content”][et_pb_image src=”https:\/\/regenerative-thermal-oxidizers.com\/wp-content\/uploads\/2024\/10\/0-Waste-heat-recovery-coating-industry-2.webp” _builder_version=”4.27.0″ _module_preset=”default” theme_builder_area=”post_content” alt=”Waste heat recovery coating industry ” title_text=”0-Waste heat recovery coating industry 2″ hover_enabled=”0″ sticky_enabled=”0″][\/et_pb_image][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=”4.27.0″ _module_preset=”default” theme_builder_area=”post_content”][et_pb_column _builder_version=”4.27.0″ _module_preset=”default” type=”4_4″ theme_builder_area=”post_content”][et_pb_text _builder_version=”4.27.0″ _module_preset=”default” theme_builder_area=”post_content” hover_enabled=”0″ sticky_enabled=”0″]<\/p>\n
[\/et_pb_text][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=”4.27.0″ _module_preset=”default” column_structure=”3_5,2_5″ theme_builder_area=”post_content” hover_enabled=”0″ sticky_enabled=”0″][et_pb_column _builder_version=”4.27.0″ _module_preset=”default” type=”3_5″ theme_builder_area=”post_content”][et_pb_image src=”https:\/\/regenerative-thermal-oxidizers.com\/wp-content\/uploads\/2024\/10\/0-Waste-heat-recovery-coating-industry-3.webp” _builder_version=”4.27.0″ _module_preset=”default” theme_builder_area=”post_content” alt=”Waste heat recovery coating industry” title_text=”0-Waste heat recovery coating industry 3″ hover_enabled=”0″ sticky_enabled=”0″][\/et_pb_image][\/et_pb_column][et_pb_column _builder_version=”4.27.0″ _module_preset=”default” type=”2_5″ theme_builder_area=”post_content”][et_pb_image src=”https:\/\/regenerative-thermal-oxidizers.com\/wp-content\/uploads\/2024\/10\/0-Waste-heat-recovery-coating-industry-4.webp” _builder_version=”4.27.0″ _module_preset=”default” theme_builder_area=”post_content” alt=”Waste heat recovery coating industry” title_text=”0-Waste heat recovery coating industry 4″ hover_enabled=”0″ sticky_enabled=”0″][\/et_pb_image][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=”4.27.0″ _module_preset=”default” theme_builder_area=”post_content”][et_pb_column _builder_version=”4.27.0″ _module_preset=”default” type=”4_4″ theme_builder_area=”post_content”][et_pb_text _builder_version=”4.27.0″ _module_preset=”default” theme_builder_area=”post_content” hover_enabled=”0″ sticky_enabled=”0″]<\/p>\n
[\/et_pb_text][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=”4.27.0″ _module_preset=”default” column_structure=”3_5,2_5″ theme_builder_area=”post_content” hover_enabled=”0″ sticky_enabled=”0″][et_pb_column _builder_version=”4.27.0″ _module_preset=”default” type=”3_5″ theme_builder_area=”post_content”][et_pb_image src=”https:\/\/regenerative-thermal-oxidizers.com\/wp-content\/uploads\/2024\/10\/0-Waste-heat-recovery-coating-industry-5.webp” _builder_version=”4.27.0″ _module_preset=”default” theme_builder_area=”post_content” alt=”Waste heat recovery coating industry” title_text=”0-Waste heat recovery coating industry 5″ hover_enabled=”0″ sticky_enabled=”0″][\/et_pb_image][\/et_pb_column][et_pb_column _builder_version=”4.27.0″ _module_preset=”default” type=”2_5″ theme_builder_area=”post_content”][et_pb_image src=”https:\/\/regenerative-thermal-oxidizers.com\/wp-content\/uploads\/2024\/10\/0-Waste-heat-recovery-coating-industry-6.webp” _builder_version=”4.27.0″ _module_preset=”default” theme_builder_area=”post_content” alt=”Waste heat recovery coating industry” title_text=”0-Waste heat recovery coating industry 6″ hover_enabled=”0″ sticky_enabled=”0″][\/et_pb_image][\/et_pb_column][\/et_pb_row][\/et_pb_section][et_pb_section fb_built=”1″ theme_builder_area=”post_content” _builder_version=”4.27.0″ _module_preset=”default”][et_pb_row _builder_version=”4.27.0″ _module_preset=”default” global_colors_info=”{}” collapsed=”on” theme_builder_area=”post_content”][et_pb_column type=”4_4″ _builder_version=”4.27.0″ _module_preset=”default” global_colors_info=”{}” theme_builder_area=”post_content”][et_pb_text _builder_version=”4.27.0″ _module_preset=”default” header_2_font=”Arial|800|||||||” header_2_text_align=”center” global_colors_info=”{}” theme_builder_area=”post_content”]<\/p>\n
[\/et_pb_text][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=”4.27.0″ _module_preset=”default” global_colors_info=”{}” collapsed=”on” theme_builder_area=”post_content”][et_pb_column type=”4_4″ _builder_version=”4.27.0″ _module_preset=”default” global_colors_info=”{}” theme_builder_area=”post_content”][et_pb_image src=”https:\/\/regenerative-thermal-oxidizers.com\/wp-content\/uploads\/2024\/10\/0-RT-solutions-for-coating-industry-2.webp” alt=”RTO solutions for coating industry” title_text=”0-RTO solutions for coating industry 2″ _builder_version=”4.27.0″ _module_preset=”default” global_colors_info=”{}” theme_builder_area=”post_content”][\/et_pb_image][et_pb_text _builder_version=”4.27.0″ _module_preset=”default” global_colors_info=”{}” theme_builder_area=”post_content”]<\/p>\n
Por exemplo, uma m\u00e1quina de revestimento possui 8 fornos, o volume total de exaust\u00e3o dos fornos \u00e9 de 10.000 m\u00b3\/h e a temperatura m\u00e9dia dos fornos \u00e9 de 140 \u00b0C (a temperatura m\u00e9dia das zonas de alta e baixa temperatura dos 8 fornos). Ent\u00e3o, o consumo de energia do forno de uma m\u00e1quina de revestimento \u00e9<\/p>\n
<\/p>\n
[\/et_pb_text][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=”4.27.0″ _module_preset=”default” global_colors_info=”{}” theme_builder_area=”post_content”][et_pb_column type=”4_4″ _builder_version=”4.27.0″ _module_preset=”default” global_colors_info=”{}” theme_builder_area=”post_content”][et_pb_text _builder_version=”4.27.0″ _module_preset=”default” header_2_font=”Arial|800|||||||” header_2_text_align=”center” global_colors_info=”{}” theme_builder_area=”post_content”]<\/p>\n
[\/et_pb_text][et_pb_text _builder_version=”4.27.0″ _module_preset=”default” global_colors_info=”{}” theme_builder_area=”post_content”]<\/p>\n
<\/p>\n
Classifica\u00e7\u00e3o de produtos de revestimento<\/strong><\/td>\n| Comprimento do forno<\/strong><\/td>\n | Volume de ar de exaust\u00e3o de refer\u00eancia<\/strong><\/td>\n | Temperatura do ar de exaust\u00e3o<\/strong><\/td>\n<\/tr>\n | Consum\u00edveis de publicidade<\/td>\n | 24 m\uff5e40 m<\/td>\n | 9000m\u00b3\/h \uff5e 10000m\u00b3\/h<\/td>\n | 60\u2103\uff5e80\u2103<\/td>\n<\/tr>\n | Alum\u00ednio anodizado (papel de transfer\u00eancia)<\/td>\n | 12 m\uff5e24 m<\/td>\n | 8000m\u00b3\/h \uff5e 10000m\u00b3\/h<\/td>\n | 60\u2103\uff5e70\u2103<\/td>\n<\/tr>\n | Pel\u00edcula refletiva, material refletivo<\/td>\n | 24 m\uff5e72 m<\/td>\n | 7000m\u00b3\/h \uff5e 10000m\u00b3\/h<\/td>\n | 70\u2103\uff5e80\u2103<\/td>\n<\/tr>\n | Pel\u00edcula de painel solar<\/td>\n | 20 m\uff5e32 m<\/td>\n | 8000m\u00b3\/h \uff5e 10000m\u00b3\/h<\/td>\n | 70\u2103\uff5e80\u2103<\/td>\n<\/tr>\n | Filme pl\u00e1stico de alum\u00ednio<\/td>\n | 24 m\uff5e32 m<\/td>\n | 9000m\u00b3\/h \uff5e 12000m\u00b3\/h<\/td>\n | 70\u2103\uff5e80\u2103<\/td>\n<\/tr>\n | Fita<\/td>\n | 16 m\uff5e28 m<\/td>\n | 10000m\u00b3\/h \uff5e 12000m\u00b3\/<\/td>\n | 60\u2103\uff5e80\u2103<\/td>\n<\/tr>\n | Lan\u00e7amento do filme<\/td>\n | 20 m\uff5e36 m<\/td>\n | 9000m\u00b3\/h \uff5e 10000m\u00b3\/h<\/td>\n | 60\u2103\uff5e100\u2103<\/td>\n<\/tr>\n | Pel\u00edcula protetora<\/td>\n | 24 m\uff5e36 m<\/td>\n | 9000m\u00b3\/h \uff5e 10000m\u00b3\/h<\/td>\n | 70\u2103\uff5e80\u2103<\/td>\n<\/tr>\n | Separador de bateria de l\u00edtio<\/td>\n | cerca de 28m<\/td>\n | cerca de 35000m\u00b3\/h<\/td>\n | 40\u2103\uff5e60\u2103<\/td>\n<\/tr>\n | Filme fotossens\u00edvel<\/td>\n | cerca de 60m<\/td>\n | cerca de 50000m\u00b3\/h<\/td>\n | 70\u2103\uff5e80\u2103<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n | [\/et_pb_text][et_pb_text _builder_version=”4.27.0″ _module_preset=”default” global_colors_info=”{}” theme_builder_area=”post_content”]<\/p>\n \t\t\r\n\t\t\r\n\t\t |