{"id":5655,"date":"2026-03-25T07:10:42","date_gmt":"2026-03-25T07:10:42","guid":{"rendered":"https:\/\/regenerative-thermal-oxidizers.com\/?post_type=product&p=5655"},"modified":"2026-03-26T03:12:36","modified_gmt":"2026-03-26T03:12:36","slug":"dry-type-converter-gas-esp","status":"publish","type":"product","link":"https:\/\/regenerative-thermal-oxidizers.com\/bg\/produkt\/dry-type-converter-gas-esp\/","title":{"rendered":"Dry Type Converter Gas ESP Electrostatic Precipitator"},"content":{"rendered":"

 <\/p>\n

\n
\n

Metallurgical Gas Purification | Dry Type Converter Gas ESP<\/span><\/h2>\n

Master the most complex metallurgical exhaust challenges with absolute safety. Engineered by Ever-power, our Cylindrical Dry Type Converter Gas Electrostatic Precipitator features a 100% zero-leakage design and an ultra-robust 0.2 MPa pressure-bearing capacity to safely purify explosive CO gas mixtures. Eliminate detonation risks, achieve emissions below 10mg\/Nm3, and unlock maximum energy recovery from your tilting converter operations.<\/p>\n

Request Engineering Sizing<\/a><\/p>\n<\/div>\n<\/header>\n

 <\/p>\n

\n

\u2699\ufe0f Executive Engineering Brief<\/h2>\n
\n
\n

? Gas Processing Capacity<\/h3>\n
    \n
  • ? Max Gas Volume:<\/strong> 1,400,000 m3\/h<\/li>\n
  • ?\ufe0f Gas Temperature:<\/strong> 80 – 160 \u00b0C<\/li>\n
  • ?\ufe0f Inlet Dust Density:<\/strong> Up to 50 g\/Nm3<\/li>\n
  • ?\ufe0f Max Suction Pressure:<\/strong> -5,000 Pa<\/li>\n
  • ? Supported Units:<\/strong> 18 – 450 MW scale<\/li>\n<\/ul>\n<\/div>\n
    \n

    ?\ufe0f Structural & Safety Integrity<\/h3>\n
      \n
    • ? Casing Shape:<\/strong> Cylindrical (Explosion-Proof)<\/li>\n
    • ? Gas Sealing:<\/strong> 100% Zero Leakage Design<\/li>\n
    • ?\ufe0f Pressure Bearing:<\/strong> Up to 0.2 MPa<\/li>\n
    • ? Safety Mechanism:<\/strong> Integrated Relief Valves<\/li>\n
    • ? \u041e\u043f\u0435\u0440\u0430\u0446\u0438\u044f:<\/strong> Handles Intermittent Flows<\/li>\n<\/ul>\n<\/div>\n
      \n

      ? Purification Performance<\/h3>\n
        \n
      • \u2705 Outlet Emission:<\/strong> < 50 mg\/Nm3 (Capable of < 10 mg\/Nm3)<\/li>\n
      • \u2705 Internal Cleaning:<\/strong> Specialized Scraper Device<\/li>\n
      • \u2705 Dust Discharge:<\/strong> Special Dust Removal System<\/li>\n
      • \u2705 Distribution:<\/strong> High-efficiency screens<\/li>\n
      • \u2705 Lifespan:<\/strong> Designed for 20+ Years<\/li>\n<\/ul>\n<\/div>\n

        \"Dry<\/p>\n<\/div>\n<\/section>\n

        \n

        ? Deep Technical Specifications<\/h2>\n

        The Dry Type Converter Gas ESP is unequivocally one of the most critical and complex equipment pieces in the tilting converter gas purification system. Due to the high carbon monoxide (CO) content and the intermittent nature of the gas generation, strict aerodynamic and sealing specifications are mandatory.<\/p>\n

        \n\n\n\n\n\n\n\n\n\n
        Engineering Parameter<\/th>\nSpecification Standard<\/th>\nMetallurgical Impact<\/th>\n<\/tr>\n<\/thead>\n
        Casing Design Geometry<\/strong><\/td>\nCylindrical Configuration<\/td>\nEliminates 90-degree corners to ensure optimal aerodynamic characteristics, completely preventing the formation of flammable gas\/air mixtures and dangerous “blind zones”.<\/td>\n<\/tr>\n
        Structural Pressure Tolerance<\/strong><\/td>\n0.2 MPa<\/td>\nBuilt as a robust pressure vessel to withstand extreme internal deflagrations and pressure surges inherent to Basic Oxygen Furnace (BOF) operations.<\/td>\n<\/tr>\n
        Leakage Rate<\/strong><\/td>\nAbsolute Zero (0%)<\/td>\n100% sealing prevents toxic and highly valuable Carbon Monoxide (CO) from escaping into the facility, ensuring personnel safety and maximum energy recovery.<\/td>\n<\/tr>\n
        Primary Safety Relief<\/strong><\/td>\nIntegrated Relief Valves<\/td>\nInstantly vents explosive pressure spikes to the atmosphere, protecting the core internal electrode framework from catastrophic structural damage.<\/td>\n<\/tr>\n
        Ash Discharge Mechanism<\/strong><\/td>\nSpecialized Scraper & Removal Device<\/td>\nUnlike standard gravity hoppers that introduce air ingress risks, this specialized mechanism reliably extracts metallurgical dust while maintaining absolute internal gas sealing.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/section>\n
        \n

        ? Process Mechanics & Internal Architecture<\/h2>\n
        \n
        \n

        The Imperative for Cylindrical Design<\/h3>\n

        The gas generated by tilting converters during the steelmaking process is highly intermittent and extremely combustible due to surges in Carbon Monoxide (CO). Standard rectangular Electrostatic Precipitators are highly dangerous in this application because gas can stagnate in corners. The Ever-power Dry Type Converter Gas ESP utilizes a strict Cylindrical Casing<\/strong>. This structural geometry forces a continuous, sweeping aerodynamic flow that eliminates return flow and dead zones, preventing explosion-inducing gas mixtures.<\/p>\n

        The Core Separation Process:<\/strong><\/p>\n

          \n
        1. The intermittent BOF gas enters through a precision distribution screen, ensuring laminar flow across the cylinder.<\/li>\n
        2. The Discharge System ionizes the gas stream under tens of thousands of volts, applying a strong negative charge to suspended metallurgical dust.<\/li>\n
        3. Driven by the Coulomb force, the charged particles aggressively migrate to the Collecting System plates, leaving the purified combustible CO gas to exit for downstream energy recovery.<\/li>\n<\/ol>\n

          \"Dry<\/p>\n<\/div>\n

          \n

          Internal Component Configuration<\/h3>\n

          The internal architecture of the Converter Gas ESP demands absolute precision to function within a pressurized, explosive environment:<\/p>\n